Description
PPL Event Indication 0x0043
This message is sent by a PPL component to report an event to the host with optional ICB data.
NOTE: All PPL Event Indication messages that originate with the CIC PPL component will have the new Virtual CIC AIB.
Sent by
CSP
Example Message (Socket Log Output for SwitchKit)
In this example, the CSP informs the host of an incoming
SIP REGISTER message:
00 0B 00 43 00 00 FF 7F 00 A7 00 0A 00
SwitchKit Code
C Structure
typedef struct {
UBYTE AddrInfo[30];
unsigned short ComponentID;
unsigned short PPLEvent;
UBYTE ICBCount;
UBYTE Data[218];
} XL_PPLEventIndication;
C++ Class
class XLC_PPLEventIndication : public XLC_InboundMessage {
public:
const UBYTE *getAddrInfo() const;
UBYTE *getAddrInfo();
void setAddrInfo(UBYTE *x);
XBYTE getSpan() const;
void setSpan(XBYTE x);
UBYTE getChannel() const;
void setChannel(UBYTE x);
UBYTE getStackID() const;
void setStackID(UBYTE x);
UBYTE getLinkID() const;
void setLinkID(UBYTE x)
XBYTE getV5ID() const;
void setV5ID(XBYTE x);
unsigned short getComponentID() const;
void setComponentID(unsigned short x);
unsigned short getPPLEvent() const;
void setPPLEvent(unsigned short x);
UBYTE getICBCount() const;
void setICBCount(UBYTE x);
const UBYTE *getData() const;
UBYTE *getData();
void setData(UBYTE *x);
};
EXS API Hex Format
MESSAGE (White) |
RESPONSE (Gray) |
||
Byte |
Field Description |
Byte |
Field Description |
0 |
Frame (0xFE) |
0 |
Frame (0xFE) |
1, 2 |
Length (0x00NN) |
1, 2 |
Length (0x0005) |
3, 4 |
Message Type (0x0043) |
3, 4 |
Message Type (0x0043) |
5 |
Reserved (0x00) |
5 |
Reserved (0x00) |
6 |
Sequence Number |
6 |
Same Sequence Number |
7 |
Logical Node ID |
7 |
Logical Node ID |
: |
AIB Address Method Depends on component being addressed.
Number of AEs to follow
AE The AE used depends on the component being addressed.
See PPL Component Addressing |
8 |
Checksum |
: |
PPL Component ID MSB, LSB See PPL Component IDs in the API Reference. |
||
: |
PPL Event MSB, LSB |
||
: |
Number of ICBs to follow (Ignore this field if no ICBs in message.) |
||
: |
ICB
0x02 Data ICBs
0x16 SS7 Protocol Violation Data 0x1C SS7 TUP Formatted Fields 0x1F SS7 Unformatted Raw Parameters 0x51 Soft Register All Switch-Initiated Messages 0x5B IP Signaling Series 3 Card ID 0x5D H.323 DTMF Signal Input Received 0x5E H.323 Signal Update Input Received 0x5F H.323 Alphanumeric Input Received 0x62 Remote Endpoints UII Capabilities
0x03 Extended Data ICBs |
||
|
Refer to Interworking TLVs if you have enabled interworking from the VoIP Protocol Configure 0x00EE message. |
||
: |
Checksum |
Data
ICB Data Length n (variable)
Data [0] First byte of MSU Data
Data [n] End of MSU Data
NOTE: If ICB length is more than 200 bytes the following applies. For example: ICB Data Length is 450 bytes:
a. Then the first frame will be sent with the first 200 bytes of MSU Data with PPL Event Indication as
0x20: "SS7 MTP Message Tracing Not Last".
b. The second frame will be sent with the next 200 bytes of MSU Data with PPL Event Indication as
0x20: "MTP Message Tracing Not Last".
c. The third frame will be sent with the next 50 bytes of MSU Data with PPL Event Indication as
0x21: "MTP Message Tracing Last".
The length and content of the data varies according to the ICB subtype. A list of valid ICBs appears in the ICB chapter.
Response Status
If the MSB of the Status field is 0x50 (NACK), the LSB indicates the NACK reason.
0x01 Invalid module type for DPC/Stack/CICcombination.
Example: Host has sent a Service State Configure message with invalid DPC/Stack/CIC.
0x02 Message received for unassigned CIC.
Example: Host has sent a PPL Event Request for unassigned CIC.
0x03 Only Extended API is supported for VCIC.