You are here: CSP API Reference > 1 EXS & SwitchKit API Messages > Reset IP Signaling Series 3 Card 0x0107
Reset IP Signaling Series 3 Card 0x0107
Type
EXS API message
Description
Reset IP Signaling Series 3 Card 0x0107
This message resets the IP Signaling Series 3 card before and/or after the IP Signaling Series 3 Card Interface is established. This message is sent directly to the IP Signaling Series 3 card and uses the extended logical node ID format.
You can also reset the IP Signaling Series 3 card using the Reset Configuration 0x000B message once the IP Signaling Series 3 Card Interface is established.
Sent by
Example Message
The follow sample resets the IP Signaling Series 3 card when the IP Signaling Series 3 card ID or Matrix ID is not assigned.
00 11 01 07 00 00 fe 00 02 52 02 ff ff 53 04 00 20 ff ff
SwitchKit Code
C Structure
typedef struct {
UBYTE AddrInfo[4];
unsigned short ExpandedNode;
unsigned short ObjectType;
unsigned short ObjectInstanceID; ;
} XL_IPCallServerReset;
C++ Class
class XLC_IPCallServerReset: public XLC_OutboundMessage {
public:
const UBYTE *getAddrInfo() const;
UBYTE *getAddrInfo();
void setAddrInfo(UBYTE *x);
unsigned short getExpandedNode() const;
void setExpandedNode(unsigned short x);
unsigned short getObjectType() const;
void setObjectType(unsigned short x)
unsigned short getObjectInstanceID const;
void setObjectInstanceID(unsigned short x)
};
EXS API Hex Format
MESSAGE (White) |
RESPONSE (Gray) |
||
Byte |
Field Description |
Byte |
Field Description |
0 |
Frame (0xFE) |
0 |
Frame (0xFE) |
1, 2 |
Length (0xNNNN) |
1, 2 |
Length (0x000B) |
3, 4 |
Message Type (0x0107) |
3, 4 |
Message Type (0x0107) |
5 |
Reserved (0x00) |
5 |
Reserved (0x00) |
6 |
Sequence Number |
6 |
Sequence Number (same as message) |
7 |
Extended Logical Node ID (0xFE) |
7 |
Logical Node ID (0xFE) |
8 : |
Address Method 0x00 - Individual AEs |
8, 9 |
|
Number of AEs to follow |
|||
AE |
10-15 |
AIB (same as message)
|
|
: |
Checksum
|
16-19 |
AIB (same as message)
|
: |
Checksum |