SS7 Raw Data to Host

Overview

The SS7 Raw Data to Host feature allows the customer a way of tracking all Message Signaling Units (MSUs) and Link Status Signaling Units (LSSUs) transmitted to the network and received from the network.

This feature allows the SS7 Series 3 and SS7 PQ cards to send PPL event indications containing LSSUs and MSUs (received from the network as well as sent to the network) to the host. The PPL Configure (0x00D7) message is used to enable and disable (default) the feature.

Configuring the Feature

This feature is initiated by setting (enabling) configuration bytes 0x10 in the following PPL components:

Enabling the PPL event indications containing the raw LSSUs for transmission/reception to and from the network is done by enabling the configuration bytes 0x10 in the MTP2 LSC and MTP2 IAC PPL components.

Enabling the PPL event indications containing the raw MSUs for transmission/reception to and from the network is done by enabling the configuration bytes 0x10 in MTP3 HMDT and HMRT PPL components.

When the feature is enabled all the supported LSSUs and MSUs are reported to the host in the PPL event indication.

LSSUs Supported

The supported LSSUs are as follows:

MPT2 IAC (0x0022)

Status Indicator of Out of alignment (SIO)

Status Indicator of Normal (SIN)

Status Indicator of Emergency (SIE)

MPT2 LSC (0x0023)

Status Indicator of Out of Service (SIOS)

Status Indicator of Processor Outage (SIPO)

PPL Changes

This feature supports the following PPL changes:

MTP3 HMDT (0x002B)

MTP3 HMRT (0x002C)

MTP2 IAC (0x0022)

MTP2 LSC (0x0023)

Atomic Function 98