Table 8-17 CPA Class Parameters and Definitions
Class Parameter |
Definition |
---|---|
Mode |
Call Progress Analysis Mode (for example, Advanced Answer Detect, Energy Detection). |
Tone Burst Answer Threshold |
The number of frequency bursts in 500ms before answer is declared. |
Start Delay |
Amount of time to wait before analysis begins. |
Continuous Silence Timeout |
Amount of time after CPA is initiated to wait to hear any tone. |
Confirmation |
Amount of time to wait to detect a pattern. |
Confirmation/No Report |
Amount of time after detection of a tone to wait for pattern confirmation before terminating CPA. |
Minimum Frequency Glitch Time |
Amount of time to validate a tone detection. |
Minimum Silence Glitch Time |
Amount of time to validate a silence detection. |
Maximum On Timer |
The maximum amount of time a tone must be "on" without a pattern match before the "continuous on" result is reported. |
Maximum Off Timer |
The maximum amount of time silence must be detected before the "not determined" result is reported; amount of time to validate a silence detection before declaring it as silence. |
Mode Specific Value |
Values to configure for specific CPA mode. |