You are here: CSP Developer’s Guide: Overview > 8 DSP Series 2 Cards Product Description > CPA Pattern Parameter Definitions
CPA Pattern Parameter Definitions
Table 8-14 CPA Pattern Parameter definitions
Pattern ID |
Description |
---|---|
Configuration Bits |
Pattern-specific configuration (see CPA Pattern Configure message) 0x01 = Last Interval Continuous (for pattern ending with continuous tone) 0x02 = Detect Tone After Determination (for reporting Intercept Tones) 0x04 = Use As Internal Dial Tone (to detect dial tone without invoking Call Progress Analysis) |
CPA Result on Pattern Loss |
Call Progress Analysis Result to report when a pattern has been matched but discontinues before "interval cycles to report". (CPA Result message). |
Interval Cycles to Match |
The number of times an Interval Sequence must be repeated before declaring the pattern valid |
Interval Cycles to Report |
The number of times an Interval Sequence must be repeated before reporting a Call Progress Result to the host |
Interval Descriptor Count |
The number of Interval Descriptors in the pattern |
Interval Descriptor |
An Interval Descriptor is a list of the tones and intervals that constitute a pattern. The CSP uses the Interval Descriptor to confirm that a specific pattern has been detected. An Interval Descriptor consists of the Tone ID, Min. Filter, and Max. Filter, where: Tone ID – A valid Tone ID Minimum/Maximum Filter (MSB, LSB) – Minimum and maximum duration for this tone interval - A tone is determined as valid if the on and off cycles fall within the minimum and maximum times. |