0x0643 T.30 Control Parameter Transmit Level

Use this TLV in the Generic Card Configure (0x0122) and Resource Connect (0x0127) messages to set the T.30 Control Parameter Transmit Level.

Byte

Description

0, 1

Tag: 0x0643 T.30 Control Parameter Transmit Level

2, 3

Length: 0x0002

4, 5

Value[0,1]: Transmission Level in tenths of dbm

-400 to 0dbm.
Min -400 (0xFE70)
Max 0
Default -135 (0xFF79)