0x2717 Called Party Number

Use this TLV to specify the called party number. This TLV and be used in Interworking and Standard environments.

Used in:
0x0033 NPDI Universal ICB in:
Request for Service with Data message
Route Control message

Byte

Description

0, 1

Tag 0x2717

2, 3

Length Variable

4

Value[0] Type of Number

5

Value[1] Numbering Plan Identifier and
Reverse Charge Indicator

6

Value[2] Number of Digits (N)

7

Value[3] BCD Digit Pair 1

:

Value[4] BCD Digit Pair 2

:

Value[(N+1)/2]

 

 

Half as many BCD pairs as digits.