You are here: CSP Developer’s Guide: Common Channel Signaling > 9 ISDN PPL Information > L3 Global Call Reference (0x0009)
L3 Global Call Reference (0x0009)
Purpose
This section describes the PPL configuration bytes, events and timers for the L3 Global Call Reference PPL component.
L3 Global Call Reference Configuration Bytes
Byte |
Description |
Values |
---|---|---|
0x01 |
Channel ID encoding of extension bit |
* 0x00 = Ext. bit set |
0x02 |
N316: Number of RESTART attempts |
0x02 |
0x03 |
Send FACILITY INDICATION to the host |
* 0x00 = Disabled |
0x04 |
Send FACILITY ACK INDICATION to the host |
* 0x00 = Disabled |
0x05 |
Send FACILITY REJECTED INDICATION to the host |
* 0x00 = Disabled |
0x06 |
Send RESTART to the host |
* 0x00 = Disabled |
0x07 |
Send RESTART ACK to the host |
* 0x00 = Disabled |
0x08 |
Send STATUS to the host |
* 0x00 = Disabled |
0x09 |
Send STATUS ENQUIRY to the host |
* 0x00 = Disabled |
0x0A |
Send USER INFORMATION to the host |
* 0x00 = Disabled |
|
* Default value |
|
L3 Global Call Reference L3/L5 Events
The sending of the PPL events to the host is configurable with PPL Configuration Bytes 3–10. These events are only valid using the ISDN Raw IE type (0x11).
PPL Event Request (L5 to L3) |
PPL Event Indication (L3 to L5) |
---|---|
0x0001 Facility |
0x0001 Facility Indication |
L3 Global Call Reference PPL Timers
Timer ID |
Description |
Value (default) |
---|---|---|
0x16 |
T316 |