You are here: CSP Developer’s Guide: Common Channel Signaling > 6 SCCP/TCAP > China National Variant Configuration
China National Variant Configuration
Overview
This section describes a configuration sequence to enable MTP/ SCCP/TCAP support for the China variant. Note that the MTP PPL Config Byte values are listed in SS7 PPL Information.
Important! National variants may require additional User Part and protocol modifications.
Configuration sequence
The following software configuration sequence (which does not have to be followed in the order presented) should be used to support the SS7 stack for SCCP/TCAP:
• Modify PPL Config Bytes with the PPL Configure message:
MTP3 HMDT component (0x002B)
• Set Config Byte 1 (Variant) to 0x03 (China)
MTP3 HMRT component (0x002C)
• Set Config Byte 1 (Variant) to 0x03 (China)
SCCP SCLC component (0x0065)
• Set Config Byte 1 (Variant) to 0x02 (China)
Example
In a configuration with two SS7 stacks (Stack 00 and Stack 01), the following PPL Configure messages would be sent to the Excel platform. The shaded columns (asterisk* for html documents) indicate modifications. Abbreviations used in the table are:
• Seq. No. - Sequence Number
• LNI - Logical Node ID
• PPL Comp. ID - PPL Component ID
Length |
Message |
Reserve Byte |
Seq. No. |
LNI |
Stack* |
PPL Comp. |
PPL |
# Data |
Byte |
Data* |
|
---|---|---|---|---|---|---|---|---|---|---|---|
00 10 |
00 D7 |
00 |
00 |
FF |
00 01 18 01 |
00 |
00 2B |
01 |
01 |
01 |
03 |
00 10 |
00 D7 |
00 |
00 |
FF |
0001 18 01 |
00 |
00 2C |
01 |
01 |
01 |
03 |
00 10 |
00 D7 |
00 |
00 |
FF |
0001 18 01 |
00 |
00 65 |
01 |
01 |
01 |
02 |
00 10 |
00 D7 |
00 |
00 |
FF |
0001 18 01 |
01 |
00 2B |
01 |
01 |
01 |
03 |
00 10 |
00 D7 |
00 |
00 |
FF |
0001 18 01 |
01 |
00 2C |
01 |
01 |
01 |
03 |
00 10 |
00 D7 |
00 |
00 |
FF |
0001 18 01 |
01 |
00 65 |
01 |
01 |
01 |
02 |