You are here: CSP Developer’s Guide: Common Channel Signaling > 7 SS7 PPL Information > BT IUP SPRC (0x0053)
Purpose
This section includes PPL Config Bytes, all PPL events, and Timer information for the PPL Component BT IUP SPRC, a variant of TUP SPRC.
BT IUP SPRC Configuration Bytes
Byte |
Description |
Value |
0x28 |
Number of samples in moving average |
100 |
0x29 |
Instantaneous Onset Threshold for Incoming Calls. In units of 100ms |
1000 (10 ms) |
0x2A |
Moving Average Onset Threshold for Incoming Calls. In units of 100ms. |
500 (10 ms) |
0x2B |
Abatement Threshold for Incoming calls. In units of 100ms |
100 (10 ms) |
0x2C |
Number of samples to received before clearing Incoming congestion. |
10 |
0x2D |
Instantaneous Onset Threshold for Outgoing Calls. In units of 100ms. |
1000 (10 ms) |
0x2E |
Moving Average Onset Threshold for Outgoing Calls. In units of 100ms. |
500 (10 ms) |
0x2F |
Abatement Threshold for Outgoing Calls. In units of 100ms. |
100 (10 ms) |
0x30 |
Number of samples to receive before clearing Outgoing congestion. |
10 |
BT IUP SPRC PPL Event Indications to Host
Event ID |
Event |
0x01F4 |
Unknown Message Received |
0x01F5 |
Message received on Un-equipped CIC |
BT IUP SPRC PPL Timers
Timer ID |
Timer |
Default Value (10ms) |
---|---|---|
0x02 |
Time between sending queue probes |
100 |