ISUP CRO (0x0083)

Purpose

This section includes ANSI (only) PPL Config Bytes, all PPL Events, and Timer information for the PPL Component ISUP CRO.

ISUP CRO Configuration Bytes (ANSI)

Bytes 1–5 define the format of the COT message. These should not be changed.

Byte

Description

Value

0x01

Information Length

0x04

0x02

Message ID

0x05 (COT)

0x03

Parameter Count

0x01

0x04

Parameter 1 ID

0x10 (Continuity Indicators)

0x05

Parameter 1 Data Length

0x00

0x06–0x09

Not Used

 

0x0A

Continuity Recheck

0x00=Disable

0x01=Enable (default)

0x0B

Number of times to recheck

2 (default)

0x14

Total data length of release message

0x06

0x15

Release message type

0x0C

0x16

Parameter count

0x01

0x17

Parameter Type

0x12

0x18

Parameter Data Length

0x02

0x19

Data[0]

0x80

0x1A

Data[1]

0xA9

ISUP CRO PPL Event Indications (ANSI)

Event ID

Event

0x01

Subsequent Continuity Recheck attempt successful

0x02

T5 expiry in Wait for Release Complete State

0x03

1st Continuity Recheck attempt failure

0x04

Continuity Recheck attempt failure

0x05

1st Continuity Recheck attempt successful

ISUP CRO PPL Timers (ANSI)

Timer ID

Timer

Default Value (10ms)

0x01

T1

1500

0x05

T5

6000

0x19

T25

1000

0x0A

T26

18000