ISUP CVR (0x0079)

Purpose

This section includes ANSI PPL Config Bytes, all PPL Events, and Timer information for the PPL Component ISUP CVR.

 

 

ISUP CVR Configuration Bytes (ANSI)

For the CLLI and CIN parameter formats in the table below, refer to ANSI T1-113.

Byte

Description

Value

0x01

CLII

0x00=Not Configured

0x01=Configured (default)

0x02

CIN

0x00=Not configured

0x01=Configured (default)

0x03

CGC Indicator

0x00 (default)

Bits 1, 0=Circuit Group Carrier Indicator

00=Unknown

01=Analog

10=Digital

11=Digital and Analog.

 

Bits 3, 2=Double Seizing Indicator

00=Always 00; configuration taken from CPC data. DO NOT CHANGE

 

Bits 5, 4=Alarm Carrier Indicator

00=Unknown

01=Software Carrier Handling

10=Hardware Carrier Handling

11=Spare

 

Bits 7, 6- Continuity Check Requirement Indicator

00=Unknown; 01=None; 10=Statistical; 11=Per Call

0x04

Message ID

0xEB (CVR)

0x05

Number of Mandatory Parameters

2 (default)

0x06

CVR Indicator Parameter Code

0xE6

0x07

CVR Indicator Parameter Length

0x01

0x08

CGC Parameter Code

0xE5

0x09

CGC Parameter Length

0x01

0x55

CVT Indication to host

0x00=Disable (default)

0x01=Enable

ISUP CVR PPL Event Indications (ANSI)

Event ID

Event

0x01

CVT received