ISUP PPL Information for Other PPL Components

Purpose

The tables below show the ITU and ANSI PPL Event Indications and PPL Timers supported for ISUP components not previously described.The following events are only informational indications, and require no specific host response.

ISUP PPL Event Indications for Other PPL Components (ITU)

PPL Component

Event ID

Event

BLS (0x0016)

0x01

First Expiration of T13

0x02

First Expiration of T15

CRS (0x0018)

0x01

First Expiration of T17

CRCR (0x0044)

0x01

REL received with check indicator set to ‘3’

0x02

T27 timer expiration

0x03

Second failure of COT

CGRS (0x001B)

0x01

First Expiration of T23

 

0x02

UCIC Stop request received

CGRR (0x001C)

0x01

Wait for CPC Reset TO, remote reset failed.

MGBS (0x0045)

0x01

First Expiration of T19

0x02

First Expiration of T21

0x03

Stop event received in Wait for CGBA state

0x04

Stop event received in Wait for CGUA state

 

0x0A

CGBA Status Bit Error Handling function. (Outgoing bit set to 0. Incoming bit set to 1.)

 

0x0B

CGBA Status Bit Error Handling function. (Outgoing bit set to 1. Incoming bit set to 0.)

 

0x0C

CGUA Status Bit Error Handling function. (Outgoing bit set to 0. Incoming bit set to 1.)

 

0x0D

CGUA Status Bit Error Handling function. (Outgoing bit is set to 1. Incoming bit is set to 0.)

HGBS (0x0047)

 

 

0x01

First Expiration of T19

0x02

First Expiration of T21

0x03

Stop event received in Wait for CGBA state

0x04

Stop event received in Wait for CGUA state

 

0x0A

CGBA Status Bit Error Handling function. (Outgoing bit set to 0. Incoming bit set to 1.)

 

0x0B

CGBA Status Bit Error Handling function. (Outgoing bit set to 1. Incoming bit set to 0.)

 

0x0C

CGUA Status Bit Error Handling function. (Outgoing bit set to 0. Incoming bit set to 1.)

 

0x0D

CGUA Status Bit Error Handling function. (Outgoing bit is set to 1. Incoming bit is set to 0.)

 

ISUP PPL Event Indications for Other PPL Components (ANSI)

The table below shows the ANSI PPL Event Indications supported for ISUP components not previously described. The following events are only informational indications, and require no specific host response.

PPL Component

Event ID

Event

BLS (0x0016)

0x01

Expiration of T13

0x02

Expiration of T15

CGRR (0x001C)

0x01

Failure to receive L3p Group Reset response

CGRS (0x001B)

0x01

First Expiration of T23

0x02

UCIC Stop request received

CRS (0x0018)

0x01

First Expiration of T17

GBUS (0x001D)

0x01

Expiration of T19

0x02

Expiration of T21

0x03

CGBA status bit mismatch

0x04

CGUA status bit mismatch

0x05

Incorrect "circuit group supervision message type indicator" parameter in received circuit group (un)blocking acknowledgment.

 

ISUP PPL Timers for Other PPL Components (ITU)

The table below shows the ITU PPL Timer values for ISUP PPL components not previously described.

PPL Component

PPL Timer ID

Timer

Default Value (10ms)

BLS (0x0016)

0x01

T12

1500

0x02

T13

36000

0x03

T14

1500

0x04

T15

36000

 

0x05

White Book

6000

CRS (0x0018)

0x01

T16

1500

0x02

T17

6000

CRCR (0x0044)

0x01

T27

24000

0x02

T36

1200

CGRS (0x001B)

0x01

T22

1500

0x02

T23

30000

CGRR (0x001C)

0x01

Wait for CPC Response Timer

1500

HGBS (0x0047)

0x01

T18

1500

0x02

T19

30000

0x03

T20

1500

0x04

T21

30000

 

0x05

White Book

6000

MGBS (0x0045)

0x01

T18

1500

0x0 2

T19

30000

0x03

T20

1500

0x04

T21

30000

 

0x05

White Book

6000

ISUP PPL Timers for Other PPL Components (ANSI)

The table below shows lists the ANSI PPL Timer values for ISUP PPL components not previously described.

PPL Component

Timer ID

Timer

Default Value (10ms)

BLS (0x0016)

0x01

T12

1500

0x02

T13

6000

0x03

T14

1500

0x04

T15

2000

CRI (0x0015)

0x01

TCCR,r

2000

0x02

T27

18000

0x03

T34

1500

CRS (0x0018)

0x01

T16

1500

0x02

T17

6000

CGRS (0x001B)

0x01

T22

1500

0x02

T23

6000

CGRR (0x001C)

0x01

Wait for CPC Response Timer

1500

GBUS (0x001D)

0x01

T18

1500

0x02

T19

6000

0x03

T20

1500

0x04

T21

6000