ITU/ANSI MTP3 Timers for Various Components

Purpose

This section contains default settings for additional ITU and ANSI PPL Timers, shown below by PPL component. The MTP3 timers are accurate to 100 ms.

MTP3 PPL Timers (ITU)

.

PPL Component

Timer ID

Timer

Default Value

(10 ms)

RCAT (0x0032)

0x01

T16

175

RSRT (0x0033)

0x01

T10

4500

TCBC (0x0038)

0x01

T3

80

0x02

T4

80

0x03

T5

80

TCOC (0x0039)

0x01

T1

80

0x02

T2

140

TCRC (0x003A)

0x01

T6

80

TPRC (0x003D)

0x01

T20

6000

TRCC (0x003E)

0x01

T15

250

TSRC (0x0040)

0x01

T19

6800

0x02

T21

6400

SLTC (0x0041)

0x01

T1

800

MTP3 PPL Timers (ANSI)

This section contains default settings for ANSI PPL Timers, shown below by PPL component.

The MTP3 timers are accurate to 100 ms.

.

PPL Component

Timer ID

Timer

Default Value

(10 ms)

RCAT (0x0032)

0x01

T16

175

RSRT (0x0033)

0x01

T10

4500

TCBC (0x0038)

0x01

T3

80

0x02

T4

80

0x03

T5

80

TCOC (0x0039)

0x01

T1

80

0x02

T2

140

TCRC (0x003A)

0x01

T6

80

TPRC (0x003D)

0x01

T22

6000

0x02

T23

1000

0x03

T26

1200

TRCC (0x003E)

0x01

T15

250

TSRC (0x0040)

0x01

T25

3000

0x02

T28

1000

0x03

T29

6000

SLTC (0x0041)

0x01

T1