You are here: CSP Developer’s Guide: Common Channel Signaling > 7 SS7 PPL Information > L3P BT IUP (0x0011)
L3P BT IUP Configuration Bytes
Block 1
The L3P BT IUP configuration bytes below are included in Block 1.
Byte |
Description of Block 1 Byte |
Value |
---|---|---|
0x01 |
Generate PPL Event Indication for IAM Bit Number Message 0 Generate State 2-7 Unused |
See Note 2. 0 (default) |
0x02 |
Generate PPL Event Indication for IFAM Bit Number Message 0 Generate State 2-7 Unused |
See Note 2. 0 (default)
|
0x03 |
Generate PPL Event Indication for SAM Bit Number Message 0 Generate State 2-7 Unused |
See Note 2. 0 (default)
|
0x04 |
Generate PPL Event Indication for FAM Bit Number Message 0 Generate State 2-7 Unused |
See Note 2. 0 (default)
|
0x05 |
Generate PPL Event Indication for Send "N" Digits Bit Number Message 0 Generate State 2-7 Unused |
See Note 2. 0 (default)
|
0x06 |
Generate PPL Event Indication for Send All Digits Bit Number Message 0 Generate State 2-7 Unused |
See Note 2. 0 (default)
|
0x07 |
Generate PPL Event Indication for Send Additional Setup Information Bit Number Message 0 Generate State 2-7 Unused |
See Note 2. 0 (default)
|
0x08 |
Generate PPL Event Indication for Address Complete Bit Number Message 0 Generate State 2-7 Unused |
See Note 2. 0 (default)
|
0x09 |
Generate PPL Event Indication for Congestion Bit Number Message 0 Generate State 2-7 Unused |
See Note 2. 0 (default)
|
0x0A |
Generate PPL Event Indication for Terminal Congestion Bit Number Message 0 Generate State 2-7 Unused |
See Note 2. 0 (default)
|
0x0B |
Generate PPL Event Indication for Connection Not Admitted Bit Number Message 0 Generate State 2-7 Unused |
See Note 2. 0 (default)
|
0x0C |
Generate PPL Event Indication for Repeat Attempt Bit Number Message 0 Generate State 2-7 Unused |
See Note 2. 0 (default)
|
0x0D |
Generate PPL Event Indication for Subscriber Engaged Bit Number Message 0 Generate State 2-7 Unused |
See Note 2. 0 (default)
|
0x0E |
Generate PPL Event Indication for Subscriber Out of Order Bit Number Message 0 Generate State 2-7 Unused |
See Note 2. 0 (default)
|
0x0F |
Unused |
|
0x10 |
Unused |
|
0x11 |
Generate PPL Event Indications for Answer Bit Number Message 0 Generate State 2-7 Unused |
See Note 2. 0 (default)
|
0x12 |
Generate PPL Event Indication for Clear Bit Number Message 0 Generate State 2-7 Unused |
See Note 2. 0 (default)
|
0x13 |
Generate PPL Event Indication for Re-Answer Bit Number Message 0 Generate State 2-7 Unused |
See Note 2. 0 (default)
|
0x14 |
Generate PPL Event Indication for Release Bit Number Message 0 Generate State 2-7 Unused |
See Note 2. 0 (default)
|
0x15 |
Unused |
|
0x16 |
Unused |
|
0x17 |
Unused |
|
0x18 |
Unused |
|
0x19 |
Generate PPL Event Indications for Circuit Free Bit Number Message 0 Generate State 2-7 Unused |
Note 2 0 (default)
|
0x1A |
Generate PPL Event Indication for Blocking Bit Number Message 0 Generate State 2-7 Unused |
See Note 2. 0 (default)
|
|
|
|
0x1B |
Generate PPL Event Indication for Unblocking Bit Number Message 0 Generate State 2-7 Unused |
See Note 2. 0 (default)
|
0x1C |
Generate PPL Event Indication for Block Ack Bit Number Message 0 Generate State 2-7 Unused |
See Note 2. 0 (default)
|
0x1D |
Generate PPL Event Indication for Unblock Ack Bit Number Message 0 Generate State 2-7 Unused |
See Note 2. 0 (default)
|
0x1E |
Generate PPL Event Indication for Overload Bit Number Message 0 Generate State 2-7 Unused |
See Note 2. 0 (default)
|
0x1F |
Unused |
|
0x20 |
Unused |
|
0x21 |
Unused |
|
0x22 |
Unused |
|
0x23 |
Unused |
|
0x24 |
Unused |
|
0x25 |
Generate PPL Event Indication for Confusion Bit Number Message 0 Generate State 2-7 Unused |
See Note 2. 0 (default)
|
0x26 |
Generate PPL Event Indication for ISDN Composite Service Info Bit Number Message 0 Generate State 2-7 Unused |
See Note 2. 0 (default)
|
0x27 |
Unused |
|
0x28 |
Unused |
|
0x29 |
Generate PPL Event Indications for Additional Call Information Bit Number Message 0 Generate State 2-7 Unused |
See Note 2. 0 (default)
|
0x2A |
Unused |
|
0x2B |
Unused |
|
0x2C |
Generate PPL Event Indication for Swap Bit Number Message 0 Generate State 2-7 Unused |
See Note 2. 0 (default)
|
0x2D |
For the AUTO (IAM-SND) protocol: The number of accumulated digits received must be greater than or equal to this value to prevent another SND message from being sent. For the AUTO (IAM-SAD) protocol: The number of accumulated digits received must be greater than or equal to this value to prevent another SAD message from being sent. See config block 1, byte 0x2E for setting of the AUTO (IAM-SND) or AUTO (IAM-SAD) modes. NOTE: If more than 30 digits are received the channel will be purged. |
0 = Default |
0x2E |
IAM Operational Mode. Auto(IAM-SND)/Host/AUTO(IAM-SAD) control of messaging on reception of an IAM. In Auto IAM-SND Mode the PPL code will automatically attempt to retrieve the Desires number of Digits based upon the setting in the above config byte using the SND protocol. In Host mode the Host must request any desired additional digits, and ACI messages, if required. It must deal with the networks responses appropriately. In the AUTO IAM-SAD mode the PPL code will automatically attempt to retrieve at least the desired number of digits based upon the setting in the above config byte or timer 0x16 expiring or the reception of a FAM using the SAD protocol. |
0 = Default AUTO IAM-SND 1 = Host CTRL 2 = AUTO IAM-SAM
|
0x2F
|
IFAM Operational Mode. This controls the PPL processing by selection of one of two actions. L3p takes these actions after the IFAM is received and a Setup message is sent to L4. In the Basic processing mode, the PPL waits for L4 to issue an Alerting message, or any other Host desired message wrapped in a PPL Event Request. In the Auto mode, the PPL will issue an ACI/ASUI message to L3 and await it’s response. Once received it will send a PPL Event Indication of ACI/ASUI to the Host. ACI is sent whenever the received Interworking bit in the IAM/IFAM message, is zero and ASUI when the bit is a one. The ACI/ASUI responses will be generated by the PPL code whenever a valid request is received regardless of this config byte’s setting.
Auto response to ACI request messages. PNI processing. When enabled, and the PNI bit is set will cause up to 2 Auto ACI requests to be issued. As defined in config block 1 bytes 0x60 and 0x61. |
Bit 0 0 = Default, Auto ACI/ASUI 1 = Basic
Bit 1 0 = Default, Auto respond to ACI request. 1 = Do not respond automatically to ACI request. Allow Host to respond.
Bit 2 0 = Disabled 1 = Enabled |
0x30 |
L3p IUP Setup Report Format. Bit Number Message 0 ICB encoding to use whenever L3pIUP is required to issue a Setup msg to L4.
1-7 Unused |
0, Report using actual IUP ICBs = Default. 1, Report only the called address (optionally calling address) using Stage N Address Data ICB in BCD. |
0x31 |
Network Configuration Bit Number Description 0 Unused 1 Unidirectional/Both way.
2 Exchange Type |
0 = Default, Both way 1= Unidirectional 0 = Terminating 1 = Intermediate |
0x32 |
Out Of Service to Inservice transition notification. 0 = Send UBL (Unblock) to network 1 = Send nothing |
0 = Default |
0x33 |
Control Reporting of Call Connected upon receiving ANS. 0 = Suppress Message 1 = Issue PPL Event Indication message |
1 = Default |
0x34 |
The RFS with data will not be reported to the HOST until after the results of the ACI/SASUI is collected. The Host will be presented with a single IUP ICB containing the original IAM/IFAM message and the received ACI/SASUI response. When this byte is set, config block 1, byte 0x2F is ignored, but it’s functionality is activated to get the ACI/ASUI responses |
0 = Default Disable late RFS reporting. 1 = Enable RFS reporting after auto ACI request/response. |
0x35 |
Outgoing Congestion Control |
0= Enabled- Default. 1 = Disabled. |
0x36 |
For the AUTO (IAM-SND) or AUTO (IAM-SAD) protocol: The Minimum number of accumulated digits when a FAM is received. If this minimum is not satisfied the call will be denied via a CAN. Use config block 1, byte 0x2D to set the minimum number of IAM/SAM digits to receive. |
0 = Default |
0x37 |
Number of digits to match. If these digits match the digits in the accumulated digit buffer then use the value in config block 1, byte 0x3D in stead of config byte 0x2D to limit the number of SNDs/SADs to issue. And use the value in config block 1, byte 0x3E in stead of config byte 0x36 to set the minimum number of digits required when a FAM is received. |
0 = Default |
0x38 |
First two digits to match |
0 = Default |
0x39 |
Second two digits to match |
0 = Default |
0x3A |
Third two digits to match |
0 = Default |
0x3B |
Fourth two digits to match |
0 = Default |
0x3C |
Fifth two digits to match |
0 = Default |
0x3D |
Alternate minimum number of digits that must be received to prevent another SND or SAD to be issued. Used instead of config block 1, byte 0x2D. |
0 = Default |
0x3E |
Alternate minimum number of digits that must be received to successfully allow a FAM to complete the address information. Used in stead of config block 1, byte 0x36. |
0 = Default |
0x3F-0x5F |
Unused |
|
0x60 |
When PNI processing is enabled, The Auto ACI IRC value to be used when the PNI bit is clear, or the second Auto ACI IRC value to be used when the PNI is set. When PNI processing is disabled this contains the Auto ACI IRC value. |
0 = Don’t issue Request. 1 = Default |
0x61 |
When PNI processing is enabled, The first Auto ACI IRC value to be used when the PNI bit is set. |
0 = Don’t issue Request. 0 = Default |
0x62 |
Preserve Block states when DPC becomes inaccessible. |
0 = Preserve 1 = Destroy |
0x63 |
Preserve (Maintain) Answered Calls when DPC becomes inaccessible. |
0 = Preserve 1 = Destroy |
0x64 |
Beginning of IAM Message. Number of TLVs that follow |
4 |
0x65 |
H0 H1 element TLV ID |
1 |
0x66 |
Length of TLV data to follow |
2 |
0x67 |
First byte (i.e. H0) of H0 H1 |
0 |
0x68 |
Second byte (i.e. H1) of H0 H1 |
0 |
0x69 |
IAM/IFAM Message Ind. TLV ID |
2 |
0x6A |
Length of TLV data to follow |
5 |
0x6B-0x6F |
Data for this TLV |
|
0x70 |
Called Address TLV ID |
3 |
0x71 |
Length of TLV data to follow |
Variable 2 to 0x0B, 0x0B = Default |
0x72-0x7C |
Data for this TLV |
|
0x7D |
Line Identity TLV |
4 |
0x7E |
Length of TLV data to follow |
Variable 2 to 9, 9 = Default |
0x7F-0x87 |
Data for this TLV |
|
0x88 |
Beginning of IFAM Message. Number of TLVs that follow |
4 |
0x89 |
H0 H1 element TLV ID |
1 |
0x8A |
Length of TLV data to follow |
2 |
0x8B-0x8C |
Data for this TLV |
|
0x8D |
IAM/IFAM Message Ind. TLV ID |
2 |
0x8E |
Length of TLV data to follow |
5 |
0x8F-0x93 |
Data for this TLV |
|
0x94 |
Called Address TLV ID |
3 |
0x95 |
Length of TLV data to follow |
variable 2 to 0x0B, 0x0B = Default |
0x96-0xA0 |
Data for this TLV |
|
0xA1 |
Line Identity TLV ID |
4 |
0xA2 |
Length of TLV data to follow |
variable 2 to 9, 9 = Default |
0xA3-0xAB |
Data for this TLV |
|
0xAC |
Beginning of SAM Message. Number of TLVs that follow |
2 |
0xAD |
H0 H1 element TLV ID |
1 |
0xAE |
Length of TLV data to follow |
2 |
0xAF-0xB0 |
Data for this TLV |
|
0xB1 |
Reserved Data Byte TLV ID |
0x18 |
0xB2 |
Length of TLV data |
1 |
0xB3 |
Reserved byte |
0 |
0xB4 |
SAM/FAM Called Address TLV ID |
0x19 |
0xB5 |
Length of TLV data to follow |
variable 2 to 0x0A, 0x0A = Default |
0xB6-0xBF |
Data for this TLV |
|
0xC0 |
Beginning of FAM Message. Number of TLVs that follow |
2 |
0xC1 |
H0 H1 element TLV ID |
1 |
0xC2 |
Length of TLV data to follow |
2 |
0xC3-0xC4 |
Data for this TLV |
|
0xC5 |
Reserved Data Byte TLV ID |
0x18 |
0xC6 |
Length of TLV data |
1 |
0xC7 |
Reserved byte |
0 |
0xC8 |
SAM/FAM Called Address TLV ID |
0x19 |
Block 2
The L3P BT IUP configuration bytes below are included in Block 2.
Byte |
Description of Block 2 Byte |
Value |
---|---|---|
0x01 |
Length of TLV data to follow |
variable 2 to 0x0A, 0x0A = Default |
0x02-0x0B |
Data for this TLV |
|
0x0C |
Beginning of ASUI Type 1 Message. Number of TLVs that follow |
3 |
0x0D |
H0 H1 element TLV ID |
1 |
0x0E |
Length of TLV data to follow |
2 |
0x0F-0x10 |
Data for this TLV |
|
0x11 |
ASUI Message Information Contained Code TLV ID |
5 |
0x12 |
Length of TLV data to follow |
1 |
0x13 |
Data for this TLV |
0 |
0x14 |
Line Identity TLV ID |
4 |
0x15 |
Length of TLV data to follow |
Variable 2 to 9, 9 = Default |
0x16-0x1E |
Data for this TLV |
|
0x1F |
Beginning of ASUI Type 2 Message. Number of TLVs that follow |
4 |
0x20 |
H0 H1 element TLV ID |
1 |
0x21 |
Length of TLV data to follow |
2 |
0x22-0x23 |
Data for this TLV |
|
0x24 |
ASUI Message Information Contained Code TLV ID |
5 |
0x25 |
Length of TLV data to follow |
1 |
0x26 |
Data for this TLV |
0 |
0x27 |
Reserved Data Byte TLV ID |
0x18 |
0x28 |
Length of TLV data to follow |
1 |
0x29 |
Data for this TLV |
0 |
0x2A |
Partial Calling Line Identity TLV ID |
6 |
0x2B |
Length of TLV data to follow |
Variable 2 to 9, 9 = Default |
0x2C-0x34 |
Data for this TLV |
|
0x35 |
Beginning of SND Message. Number of TLVs that follow |
2 |
0x36 |
H0 H1 element TLV ID |
1 |
0x37 |
Length of TLV data to follow |
2 |
0x38-0x39 |
Data for this TLV |
|
0x3A |
Number of Digits Requested TLV ID |
7 |
0x3B |
Length of TLV data to follow |
1 |
0x3C |
Data for this TLV |
0 |
0x3D |
Beginning of SAD Message. Number of TLVs that follow |
2 |
0x3E |
H0 H1 element TLV ID |
1 |
0x3F |
Length of TLV data to follow |
2 |
0x40-0x41 |
Data for this TLV |
|
0x42 |
Reserved Data Byte TLV ID |
0x18 |
0x43 |
Length of TLV data to follow |
1 |
0x44 |
Reserved byte |
0 |
0x45 |
Beginning of SASUI Message. Number of TLVs that follow |
2 |
0x46 |
H0 H1 element TLV ID |
1 |
0x47 |
Length of TLV data to follow |
2 |
0x48-0x49 |
Data for this TLV |
|
0x4A |
SAUSI Information Indicator TLV ID |
8 |
0x4B |
Length of TLV data to follow |
1 |
0x4C |
Data for this TLV |
|
0x4D |
Beginning of ACM Message. Number of TLVs that follow |
2 |
0x4E |
H0 H1 element TLV ID |
1 |
0x4F |
Length of TLV data to follow |
2 |
0x50-0x51 |
Data for this TLV |
|
0x52 |
Address Complete Message Indicator TLV ID |
9 |
0x53 |
Length of TLV data to follow |
3 |
0x54-0x56 |
Data for this TLV |
|
0x57 |
Beginning of CNG Message. Number of TLVs that follow |
1 |
0x58 |
H0 H1 element TLV ID |
1 |
0x59 |
Length of TLV data to follow |
2 |
0x5A-0x5B |
Data for this TLV |
|
0x5C |
Beginning of TCM Message. Number of TLVs that follow |
1 |
0x5D |
H0 H1 element TLV ID |
1 |
0x5E |
Length of TLV data to follow |
2 |
0x5F-0x60 |
Data for this TLV |
|
0x61 |
Beginning of CAN Message. Number of TLVs that follow |
3 |
0x62 |
H0 H1 element TLV ID |
1 |
0x63 |
Length of TLV data to follow |
2 |
0x64-0x65 |
Data for this TLV |
|
0x66 |
CAN Reason TLV ID |
0x0A |
0x67 |
Length of TLV data to follow |
1 |
0x68 |
Data for this TLV |
|
0x69 |
CAN Diagnostics TLV ID |
0x0B |
0x6A |
Length of TLV data to follow |
1 |
0x6B |
Data for this TLV |
|
0x6C |
Beginning of ANS Message. Number of TLVs that follow |
2 |
0x6D |
H0 H1 element TLV ID |
1 |
0x6E |
Length of TLV data to follow |
2 |
0x6F-0x70 |
Data for this TLV |
|
0x71 |
Type of Answer TLV ID |
0x0B |
0x72 |
Length of TLV data to follow |
1 |
0x73 |
Data for this TLV |
|
0x74 |
Beginning of CLR Message. Number of TLVs that follow |
1 |
0x75 |
H0 H1 element TLV ID |
1 |
0x76 |
Length of TLV data to follow |
2 |
0x77-0x78 |
Data for this TLV |
|
0x79 |
Beginning of REL Message. Number of TLVs that follow |
2 |
0x7A |
H0 H1 element TLV ID |
1 |
0x7B |
Length of TLV data to follow |
2 |
0x7C-0x7D |
Data for this TLV |
|
0x7E |
Release Reason TLV ID |
0x0D |
0x7F |
Length of TLV data to follow |
1 |
0x80 |
Data for this TLV |
0x2F |
0x81 |
Beginning of CCF Message. Number of TLVs that follow |
1 |
0x82 |
H0 H1 element TLV ID |
1 |
0x83 |
Length of TLV data to follow |
2 |
0x84-0x86 |
Data for this TLV |
|
0x86 |
Beginning of BLO Message. Number of TLVs that follow |
1 |
0x87 |
H0 H1 element TLV ID |
1 |
0x88 |
Length of TLV data to follow |
2 |
0x89-0x8A |
Data for this TLV |
|
0x8B |
Beginning of UBL Message. Number of TLVs that follow |
1 |
0x8C |
H0 H1 element TLV ID |
1 |
0x8D |
Length of TLV data to follow |
2 |
0x8E-0x8F |
Data for this TLV |
|
0x90 |
Beginning of BLA Message. Number of TLVs that follow |
1 |
0x91 |
H0 H1 element TLV ID |
1 |
0x92 |
Length of TLV data to follow |
2 |
0x93-0x94 |
Data for this TLV |
|
0x95 |
Beginning of UBA Message. Number of TLVs that follow |
1 |
0x96 |
H0 H1 element TLV ID |
1 |
0x97 |
Length of TLV data to follow |
2 |
0x98-0x99 |
Data for this TLV |
|
0x9A |
Beginning of CFN Message. Number of TLVs that follow |
2 |
0x9B |
H0 H1 element TLV ID |
1 |
0x9C |
Length of TLV data to follow |
2 |
0x9D-0x9E |
Data for this TLV |
|
0x9F |
Confusion Message Qualifier TLV ID |
0x0E |
0xA0 |
Length of TLV data to follow |
1 |
0xA1 |
Data for this TLV |
|
0xA2 |
Beginning of ACI Type 1 Message. Number of TLVs that follow |
5 |
0xA3 |
H0 H1 element TLV ID |
1 |
0xA4 |
Length of TLV data to follow |
2 |
0xA5-0xA6 |
Data for this TLV |
|
0xA7 |
ACI Information Contained and Information Requested TLV ID |
0x0F |
0xA8 |
Length of TLV data to follow |
2 |
0xA9-0xAA |
Data for this TLV |
|
0xAB |
ACI Type 1 Reserved Bytes TLV ID |
0x10 |
0xAC |
Length of TLV data to follow |
2 |
0xAD-0xAE |
Data for this TLV |
|
0xAF |
ACI Type 1 Message Indicators TLV ID |
0x11 |
0xB0 |
Length of TLV data to follow |
1 |
0xB1 |
Data for this TLV |
|
0xB2 |
Line Identity TLV ID |
4 |
0xB3 |
Length of TLV data to follow |
variable 2 to 9, 9 = Default |
0xB4-0xBC |
Data for this TLV |
|
0xBD |
Beginning of ACI Type 2 Message. Number of TLVs that follow |
3 |
0xBE |
H0 H1 element TLV ID |
1 |
0xBF |
Length of TLV data to follow |
2 |
0xC0-0xC1 |
Data for this TLV |
|
0xC2 |
ACI Information Contained and Information Requested TLV ID |
0x0F |
0xC3 |
Length of TLV data to follow |
2 |
0xC4-0xC5 |
Data for this TLV |
|
0xC6 |
Partial Calling Line Identity TLV ID |
6 |
0xC7 |
Length of TLV data to follow |
Variable 2 to 9, 9 = Default |
0xC8 |
Data for this TLV |
|
Block 3
The L3P BT IUP configuration bytes below are included in Block 3.
|
Description for Block 3 Byte |
Value |
---|---|---|
1-8 |
Data for last byte of this TLV |
|
9 |
Beginning of ACI Type 3 Message. Number of TLVs that follow |
5 |
0x0A |
H0 H1 element TLV ID |
1 |
0x0B |
Length of TLV data to follow |
2 |
0x0C-0x0D |
Data for this TLV |
|
0x0E |
ACI Information Contained and Information Requested TLV ID |
0x0F |
0x0F |
Length of TLV data to follow |
2 |
0x10-0x11 |
Data for this TLV |
|
0x12 |
Calling/Called Subscriber’s Basic Service Marks TLV ID |
0x12 |
0x13 |
Length of TLV data to follow |
2 |
0x14-0x15 |
Data for this TLV |
|
0x16 |
ACI Type 3 Message Indicators TLV ID |
0x13 |
0x17 |
Length of TLV data to follow |
1 |
0x18 |
Data for this TLV |
|
0x19 |
Line Identity TLV ID |
4 |
0x1A |
Length of TLV data to follow |
variable 2 to 9, 9 = Default |
0x1B-0x23 |
Data for this TLV |
|
0x24 |
Beginning of ACI Type 4 Message. Number of TLVs that follow |
4 |
0x25 |
H0 H1 element TLV ID |
1 |
0x26 |
Length of TLV data to follow |
2 |
0x27-0x28 |
Data for this TLV |
|
0x29 |
ACI Information Contained and Information Requested TLV ID |
0x0F |
0x2A |
Length of TLV data to follow |
2 |
0x2B-0x2C |
Data for this TLV |
|
0x2D |
Calling/Called Subscriber’s Basic Service Marks TLV ID |
0x12 |
0x2E |
Length of TLV data to follow |
2 |
0x2F-0x30 |
Data for this TLV |
|
0x31 |
ACI Type 4 Message Indicators TLV ID |
0x14 |
0x32 |
Length of TLV data to follow |
1 |
0x33 |
Data for this TLV |
|
0x34 |
Beginning of ACI Type 5 Message. Number of TLVs that follow |
3 |
0x35 |
H0 H1 element TLV ID |
1 |
0x36 |
Length of TLV data to follow |
2 |
0x37-0x38 |
Data for this TLV |
|
0x39 |
ACI Information Contained and Information Requested TLV ID |
0x0F |
0x3A |
Length of TLV data to follow |
2 |
0x3B-0x3C |
Data for this TLV |
|
0x3D |
Calling Subscriber’s Originating Facility Marks TLV ID |
0x15 |
0x3E |
Length of TLV data to follow |
2 |
0x3F-0x40 |
Data for this TLV |
|
0x41 |
Beginning of ACI Type 6 Message. Number of TLVs that follow |
3 |
0x42 |
H0 H1 element TLV ID |
1 |
0x43 |
Length of TLV data to follow |
2 |
0x44-0x45 |
Data for this TLV |
|
0x46 |
ACI Information Contained and Information Requested TLV ID |
0x0F |
0x47 |
Length of TLV data to follow |
2 |
0x48-0x49 |
Data for this TLV |
|
0x4A |
Called Subscriber’s Terminating Facility Marks TLV ID |
0x16 |
0x4B |
Length of TLV data to follow |
2 |
0x4C-0x4D |
Data for this TLV |
|
0x4E |
Beginning of ACI Type 7 Message. Number of TLVs that follow |
2 |
0x4F |
H0 H1 element TLV ID |
1 |
0x50 |
Length of TLV data to follow |
2 |
0x51-0x52 |
Data for this TLV |
|
0x53 |
ACI Information Contained and Information Requested TLV ID |
0x0F |
0x54 |
Length of TLV data to follow |
2 |
0x55-0x56 |
Data for this TLV |
|
0x57 |
Beginning of OLM Message. Number of TLVs that follow |
1 |
0x58 |
H0 H1 element TLV ID |
1 |
0x59 |
Length of TLV data to follow |
2 |
0x5A-0x5B |
Data for this TLV |
|
0x5C |
Beginning of SOO Message. Number of TLVs to follow |
1 |
0x5D |
H0 H1 element TLV ID |
1 |
0x5E |
Length of TLV data to follow |
2 |
0x5F-0x60 |
Data for this TLV |
|
0x61 |
Beginning of SEM Message. Number of TLVs to follow |
1 |
0x62 |
H0 H1 element TLV ID |
1 |
0x63 |
Length of TLV data to follow |
2 |
0x64-0x65 |
Data for this TLV |
|
0x66 |
Beginning of SIM Type 1 Message Number of TLVs to follow |
2 |
0x67 |
H0 H1 element TLV ID |
1 |
0x68 |
Length of TLV data to follow |
2 |
0x69-0x6A |
Data for this TLV |
|
0x6B |
Information Contained and Information Requested |
0x0F |
0x6C |
Length of TLV data to follow |
2 |
0x6D-0x6E |
Data for this TLV |
|
0x6F |
Beginning of SIM TYPE 2 Message Number of TLVs to follow |
6 |
0x70 |
H0 H1 element TLV ID |
1 |
0x71 |
Length of TLV data to follow |
2 |
0x72-0x73 |
Data for this TLV |
|
0x74 |
Information Contained and Information Requested |
0x0F |
0x75 |
Length of TLV data to follow |
2 |
0x76-0x77 |
Data for this TLV |
|
0x78 |
Facility Indicator Code |
0x1B |
0x79 |
Length of TLV data to follow |
2 |
0x7A-0x7B |
Data for this TLV |
|
0x7C |
Service Indicator Code |
0x1D |
0x7D |
Length of TLV data to follow |
2 |
0x7E-0x7F |
Data for this TLV |
|
0x80 |
Reserved Data Byte |
0x18 |
0x81 |
Length of TLV data to follow |
1 |
0x82 |
Data for this TLV |
|
0x83 |
Line Identity (LI) |
4 |
0x84 |
Length of TLV data to follow |
Variable 2 to 9, 9 = Default |
0x85-0x8D |
Data for this TLV |
|
0x8E |
Beginning of SIM TYPE 3 Message Number of TLVs to follow |
7 |
0x8F |
H0 H1 element TLV ID |
1 |
0x90 |
Length of TLV data to follow |
2 |
0x91-0x92 |
Data for this TLV |
|
0x93 |
Information Contained and Information Requested |
0x0F |
0x94 |
Length of TLV data to follow |
2 |
0x95-0x96 |
Data for this TLV |
|
0x97 |
Facility Indicator Code |
0x1B |
0x98 |
Length of TLV data to follow |
2 |
0x99-0x9A |
Data for this TLV |
|
0x9B |
Service Indicator Code |
0x1D |
0x9C |
Length of TLV data to follow |
2 |
0x9D-0x9E |
Data for this TLV |
|
0x9F |
Closed User Group Interlock Code |
0x1C |
0xA0 |
Length of TLV to follow |
4 |
0xA1-0xA4 |
Data for this TLV |
|
0xA5 |
Reserved Data Byte |
0x18 |
0xA6 |
Length of TLV data to follow |
1 |
0xA7 |
Data for this TLV |
|
0xA8 |
Line Identity (LI) |
4 |
0xA9 |
Length of TLV data to follow |
Variable 2 to 9, 9 = Default |
0xAA-0xB2 |
Data for this TLV |
|
0xB3 |
Beginning of SIM TYPE 4 Message Number of TLVs to follow |
4 |
0xB4 |
H0 H1 element TLV ID |
1 |
0xB5 |
Length of TLV data to follow |
2 |
0xB6-0xB7 |
Data for this TLV |
|
0xB8 |
Information Contained and Information Requested |
0x0F |
0xB9 |
Length of TLV data to follow |
2 |
0xBA-0xBB |
Data for this TLV |
|
0xBC |
Reserved Data Byte |
0x18 |
0xBD |
Length of TLV data to follow |
1 |
0xBE |
Data for this TLV |
|
0xBF |
Line Identity (LI) |
4 |
0xC0 |
Length of TLV data to follow |
Variable 2 to 9, 9 = Default |
0xC1-0xC8 |
Data for this TLV |
|
Block 4
The L3P BT IUP configuration bytes below are included in Block 4.
Byte |
Description of Block 4 Byte |
Value |
---|---|---|
0x01 |
Yet more Data for this TLV |
|
0x02 |
Beginning of SIM TYPE 5 Message Number of TLVs to follow |
7 |
0x03 |
H0 H1 element TLV ID |
1 |
0x04 |
Length of TLV data to follow |
2 |
0x05-0x06 |
Data for this TLV |
|
0x07 |
Information Contained and Information Requested |
0x0F |
0x08 |
Length of TLV data to follow |
2 |
0x09-0x0A |
Data for this TLV |
|
0x0B |
Facility Indicator Code |
0x1B |
0x0C |
Length of TLV data to follow |
2 |
0x0D-0x0E |
Data for this TLV |
|
0x0F |
Service Indicator Code |
0x1D |
0x10 |
Length of TLV data to follow |
2 |
0x11-0x12 |
Data for this TLV |
|
0x13 |
Reserved Data Byte |
0x18 |
0x14 |
Length of TLV data to follow |
1 |
0x15 |
Data for this TLV |
|
0x16 |
Line Identity (LI) |
4 |
0x17 |
Length of TLV data to follow |
Variable 2 to 9, 9 = Default |
0x18-0x20 |
Data for this TLV |
|
0x21 |
Six Character Network Address Extension |
0x1E |
0x22 |
Length of TLV data to follow |
Variable 2 to 7 7 = Default |
0x23-0x29 |
Data for this TLV |
|
0x2A |
Beginning of SIM TYPE 6 Message Number of TLVs to follow |
8 |
0x2B |
H0 H1 element TLV ID |
1 |
0x2C |
Length of TLV data to follow |
2 |
0x2D-0x2E |
Data for this TLV |
|
0x2F |
Information Contained and Information Requested |
0x0F |
0x30 |
Length of TLV data to follow |
2 |
0x31-0x32 |
Data for this TLV |
|
0x33 |
Facility Indicator Code |
0x1B |
0x34 |
Length of TLV data to follow |
2 |
0x35-0x36 |
Data for this TLV |
|
0x37 |
Service Indicator Code |
0x1D |
0x38 |
Length of TLV data to follow |
2 |
0x39-0x3A |
Data for this TLV |
|
0x3B |
Closed User Group Interlock Code |
0x1C |
0x3C |
Length of TLV data to follow |
4 |
0x3D-0x40 |
Data for this TLV |
|
0x41 |
Reserved Data Byte |
0x18 |
0x42 |
Length of TLV data to follow |
1 |
0x43 |
Data for this TLV |
|
0x44 |
Line Identity (LI) |
4 |
0x45 |
Length of TLV data to follow |
Variable 2 to 9, 9 = Default |
0x46-0x4E |
Data for this TLV |
|
0x4F |
Six Character Network Address Extension |
0x1E |
0x50 |
Length of TLV data to follow |
Variable 2 to 7 7 = Default |
0x51-0x57 |
Data for this TLV |
|
0x58 |
Beginning of SIM TYPE 7 Message Number of TLVs to follow |
3 |
0x59 |
H0 H1 element TLV ID |
1 |
0x5A |
Length of TLV data to follow |
2 |
0x5B-0x5C |
Data for this TLV |
|
0x5D |
Information Contained and Information Requested |
0x0F |
0x5E |
Length of TLV data to follow |
2 |
0x5F-0x60 |
Data for this TLV |
|
0x61 |
Facility Indicator Code |
0x1B |
0x62 |
Length of TLV data to follow |
2 |
0x63-0x64 |
Data for this TLV |
|
0x65 |
Beginning of SIM TYPE 8 Message Number of TLVs to follow |
5 |
0x66 |
H0 H1 element TLV ID |
1 |
0x67 |
Length of TLV data to follow |
2 |
0x68-0x69 |
Data for this TLV |
|
0x6A |
Information Contained and Information Requested |
0x0F |
0x6B |
Length of TLV data to follow |
2 |
0x6C-0x6D |
Data for this TLV |
|
0x6E |
Facility Indicator Code |
0x1B |
0x6F |
Length of TLV data to follow |
2 |
0x70-0x71 |
Data for this TLV |
|
0x72 |
Reserved Data Byte |
0x18 |
0x73 |
Length of TLV data to follow |
1 |
0x74 |
Data for this TLV |
|
0x75 |
Line Identity (LI) |
4 |
0x76 |
Length of TLV data to follow |
Variable 2 to 9, 9 = Default |
0x77-0x7F |
Data for this TLV |
|
0x80 |
Beginning of Send Service Message Number of TLVs to follow |
1 |
0x81 |
H0 H1 element TLV ID |
1 |
0x82 |
Length of TLV data to follow |
2 |
0x83-0x84 |
Data for this TLV |
|
0x85 |
Beginning of Service Message Number of TLVs to follow |
2 |
0x86 |
H0 H1 element TLV ID |
1 |
0x87 |
Length of TLV data to follow |
2 |
0x88-0x89 |
Data for this TLV |
|
0x8A |
Service Code TLV ID |
0x1F |
0x8B |
Length of TLV data to follow |
1 |
0x8C |
Data for this TLV |
|
0x8D |
Beginning of Suspend (SUS) Message Number of TLVs to follow |
2 |
0x8E |
H0 H1 element TLV ID |
1 |
0x8F |
Length of TLV data to follow |
2 |
0x90-0x91 |
Data for this TLV |
|
0x92 |
Reserved Data Byte |
0x18 |
0x93 |
Length of TLV data to follow |
1 |
0x94 |
Data for this TLV |
|
0x95 |
Beginning of Resume (RES) Message Number of TLVs to follow |
2 |
0x96 |
H0 H1 element TLV ID |
1 |
0x97 |
Length of TLV data to follow |
2 |
0x98-0x99 |
Data for this TLV |
|
0x9A |
Reserved Data Byte |
0x18 |
0x9B |
Length of TLV data to follow |
1 |
0x9C |
Data for this TLV |
|
0x9D |
Beginning of Repeat Attempt (RAM) Message Number of TLVs to follow |
1 |
0x9E |
H0 H1 element TLV ID |
1 |
0x9F |
Length of TLV data to follow |
2 |
0xA0-0xA1 |
Data for this TLV |
|
0xA2 |
Beginning of Re-answer (RAN) Message Number of TLVs to follow |
1 |
0xA3 |
H0 H1 element TLV ID |
1 |
0xA4 |
Length of TLV data to follow |
2 |
0xA5-0xA6 |
Data for this TLV |
|
0xA7 |
Beginning of SWAP Message Number of TLVs to follow |
3 |
0xA8 |
H0 H1 element TLV ID |
1 |
0xA9 |
Length of TLV data to follow |
2 |
0xAA-0xAB |
Data for this TLV |
|
0xAC |
Service Indicator Code |
0x1D |
0xAD |
Length of TLV data to follow |
2 |
0xAE-0xAF |
Data for this TLV |
|
0xB0 |
Reserved Data Byte |
0x18 |
0xB1 |
Length of TLV data to follow |
1 |
0xB2 |
Data for this TLV |
|
0xB3 |
Beginning of Operator Override Message Number of TLVs to follow |
1 |
0xB4 |
H0 H1 element TLV ID |
1 |
0xB5 |
Length of TLV data to follow |
2 |
0xB6-0xB7 |
Data for this TLV |
|
0xB8 |
Beginning of Coin and Fee Checking Message Number of TLVs to follow |
1 |
0xB9 |
H0 H1 element TLV ID |
1 |
0xBA |
Length of TLV data to follow |
2 |
0xBB-0xBC |
Data for this TLV |
|
0xBD |
Beginning of Extend Call Message Number of TLVs to follow |
1 |
0xBE |
H0 H1 element TLV ID |
1 |
0xBF |
Length of TLV data to follow |
2 |
0xC0-0xC1 |
Data for this TLV |
|
0xC2 |
Beginning of Howler Message Number of TLVs to follow |
1 |
0xC3 |
H0 H1 element TLV ID |
1 |
0xC4 |
Length of TLV data to follow |
2 |
0xC5-0xC6 |
Data for this TLV |
|
0xC7-0xC8 |
Unused |
|
Block 5
The L3P BT IUP configuration bytes below are included in Block 5.
Byte |
Description of Block 5 Byte |
Value |
---|---|---|
0x01-0x61 |
Unused |
|
0x62-0x63 |
Pointer to beginning of HLR TLVs |
4,0xC2 |
0x64-0x65 |
Pointer to beginning of ECM TLVs |
4,0xBD |
0x66-0x67 |
Pointer to beginning of CFC TLVs |
4,0xB8 |
0x68-0x69 |
Pointer to beginning of OOR TLVs |
4,0x63 |
0x6A-0x6B |
Pointer to beginning of SWAP TLVs |
4,0xA7 |
0x6C-0x6D |
Pointer to beginning of RAN TLVs |
4,0xA2 |
0x6E-0x6F |
Pointer to beginning of RAM TLVs |
4,0x9D |
0x70-0x71 |
Pointer to beginning of RES TLVs |
4,0x95 |
0x72-0x73 |
Pointer to beginning of SUS TLVs |
4,0x8D |
0x74-0x75 |
Pointer to beginning of SER TLVs |
4,0x85 |
0x76-0x77 |
Pointer to beginning of Send Service TLVs |
4,0x80 |
0x78-0x79 |
Pointer to beginning of SIM TYPE 8 TLVs |
4,0x65 |
0x7A-0x7B |
Pointer to beginning of SIM TYPE 7 TLVs |
4,0x58 |
0x7C-0x7D |
Pointer to beginning of SIM TYPE 6 TLVs |
4,0x2A |
0x7E-0x7F |
Pointer to beginning of SIM TYPE 5 TLVs |
4,2 |
0x80-0x81 |
Pointer to beginning of SIM TYPE 4 TLVs |
3,0x63 |
0x82-0x83 |
Pointer to beginning of SIM TYPE 3 TLVs |
3,0x8E |
0x84-0x85 |
Pointer to beginning of SIM TYPE 2 TLVs |
3,0x6F |
0x86-0x87 |
Pointer to beginning of SIM TYPE 1 TLVs |
3,0x66 |
0x88-0x89 |
Pointer to beginning of SEM TLVs |
3,0x61 |
0x8A-0x8B |
Pointer to beginning of SOO TLVs |
3,0x5C |
0x8C-0x8D |
Pointer to beginning of OLM TLVs |
3,0x57 |
0x8E-0x8F |
Pointer to beginning of ACI TYPE 7 TLVs |
3,0x4E |
0x90-0x91 |
Pointer to beginning of ACI TYPE 6 TLVs |
3,0x41 |
0x92-0x93 |
Pointer to beginning of ACI TYPE 5 TLVs |
3,0x34 |
0x94-0x95 |
Pointer to beginning of ACI TYPE 4 TLVs |
3,0x24 |
0x96-0x97 |
Pointer to beginning of ACI TYPE 3 TLVs |
3,9 |
0x98-0x99 |
Pointer to beginning of ACI TYPE 2 TLVs |
2,0xBD |
0x9A-0x9B |
Pointer to beginning of ACI TYPE 1 TLVs |
2,0xA2 |
0x9C-0x9D |
Pointer to beginning of CFN TLVs |
2,0x9A |
0x9E-0x9F |
Pointer to beginning of UBA TLVs |
2,0x95 |
0xA0-0xA1 |
Pointer to beginning of BLA TLVs |
2,0x90 |
0xA2-0xA3 |
Pointer to beginning of ULB TLVs |
2,0x8B |
0xA4-0xA5 |
Pointer to beginning of BLO TLVs |
2,0x86 |
0xA6-0xA7 |
Pointer to beginning of CCF TLVs |
2.0x81 |
0xA8-0xA9 |
Pointer to beginning of REL TLVs |
2,0x79 |
0xAA-0xAB |
Pointer to beginning of CLR TLVs |
2,0x74 |
0xAC-0xAD |
Pointer to beginning of ANS TLVs |
2,0x6C |
0xAE-0xAF |
Pointer to beginning of CAN TLVs |
2,0x61 |
0xB0-0xB1 |
Pointer to beginning of TCM TLVs |
2,0x5C |
0xB2-0xB3 |
Pointer to beginning of CNG TLVs |
2,0x57 |
0xB4-0xB5 |
Pointer to beginning of ACM TLVs |
2,0x4D |
0xB6-0xB7 |
Pointer to beginning of SASUI TLVs |
2,0x45 |
0xB8-0xB9 |
Pointer to beginning of SAD TLVs |
2,0x3D |
0xBA-0xBB |
Pointer to beginning of SND TLVs |
2,0x35 |
0xBC-0xBD |
Pointer to beginning of ASUI Type 2 TLVs |
2,0x1F |
0xBE-0xBF |
Pointer to beginning of ASUI Type 1 TLVs |
2,0x0B |
0xC0-0xC1 |
Pointer to beginning of FAM TLVs |
1,0xC0 |
0xC2-0xC3 |
Pointer to beginning of SAM TLVs |
1,0xAC |
0xC4-0xC5 |
Pointer to beginning of IFAM TLVs |
1,0x88 |
0xC6-0xC7 |
Pointer to beginning of IAM TLVs 0xC6 contains Block Number 1, 2, 3, 4, or 5 0x67 contains the offset to the byte within the block. Range 1 to 0xC8 |
1, 0x64 |
L3P BT IUP PPL Events
PPL Event Indications
Event ID |
Event |
---|---|
0x01F5 |
ACI Received |
0x01F6 |
SAM Received |
0x01F7 |
FAM Received |
0x01F8 |
Undefined Message Received |
0x01F9 |
Call Connected Indication |
0x01FA |
SND Received |
0x01FB |
CNG Received |
0x01FC |
CNA Received |
0x01FD |
RAM Received |
0x01FE |
SEM Received |
0x01FF |
SAD Received |
0x0200 |
CFN Received |
0x0201 |
Error, timer expired sending ACI request |
0x0202 |
Error, timer expired sending SASUI request |
0x0203 |
ASUI Received |
0x0204 |
SASUI Received |
0x0205 |
IAM Received |
0x0206 |
IFAM Received |
0x0207 |
ACM Received |
0x0208 |
TCM Received |
0x0209 |
SOO Received |
0x020A |
ANS Received |
0x020B |
CLR Received |
0x020C |
RAN Received |
0x020D |
REL Received |
0x020E |
CCF Received |
0x020F |
OLM Received |
0x0210 |
BLA Received |
0x0211 |
UBA Received |
0x0212 |
BLO Received |
0x0213 |
UBL Received |
0x0214 |
Circuit already Blocked |
0x0215 |
Circuit Not Blocked |
0x0216 |
Remote Block Indication, Circuit already Blocked |
0x0217 |
Remote Unblock Indication, Circuit not Blocked |
0x0218 |
Error Timer Expired, Sending CNA |
0x0219 |
Network ANS received before ACM |
0x021A |
SSM Received |
0x021B |
SER Received |
0x021C |
ECM Received |
0x021D |
CFC Received |
0x021E |
OOR Received |
0x021F |
HLR Received |
0x0220 |
SIM Received |
0x0221 |
SUS Received |
0x0222 |
RES Received |
0x0223 |
SWAP Received |
L3P BT IUP to Host--Access Denied Message
Whenever L3P BT IUP sends an Access Denied message to Call Control, two arguments are included: Reason and Call Status.
The table below shows the Reasons that may be sent to the host with Access Denied messages. When placing an outbound call, L3P BT IUP may determine that the call cannot be completed. When this occurs, an Access Denied message is sent to the host with the Reason fields encoded.
Reason |
Description |
---|---|
0x1B |
|
0x1C |
Outseize Failure, Glare detected. |
0x25 |
Invalid Encoding Format |
0x59 |
Outseize Failure, Call Blocked. |
Reasons for Access Denied Messages:
Call Status |
Description |
---|---|
0x00 |
Call Inactive |
0x01 |
Call Active. Call is already established on this channel. |
Call Status Values:
PPL Event Requests
Event ID |
Event |
---|---|
0x1E |
ACM |
0x1F |
ANS |
0x20 |
Undefined Message |
0x21 |
ASUI-1 |
0x22 |
ASUI-2 |
0x23 |
SND |
0x24 |
REL |
0x25 |
FAM |
0x26 |
SAM |
0x27 |
BLO |
0x28 |
UBL |
0x29 |
ACI Type 1 |
0x2A |
ACI Type 2 |
0x2B |
ACI Type 3 |
0x2C |
ACI Type 4 |
0x2D |
ACI Type 5 |
0x2E |
ACI Type 6 |
0x2F |
ACI Type 7 |
0x30 |
SASUI |
0x31 |
SSM |
0x32 |
SER |
0x33 |
ECM |
0x34 |
CFC |
0x35 |
OOR |
0x36 |
HLR |
0x37 |
SIM |
0x38 |
CLR |
0x39 |
Re-answer RAN |
0x3A |
SUS |
0x3B |
RES |
0x3C |
SWAP |
0x3D |
Block Upon Release |
L3P BT IUP PPL Timers
Timer ID |
Timer |
Default Value |
Default Duration |
---|---|---|---|
0x01 |
TO-1 |
18000 |
180 seconds |
0x02 |
TO-2 Non-receipt of answer |
12000 |
120 seconds |
0x03 |
TO-3 |
30000 |
300 seconds |
0x04 |
TO-4 |
12000 |
120 seconds |
0x05 |
Awaiting answer |
6000 |
60 seconds |
0x09 |
Awaiting appropriate backward message after IFAM/IAM/SAM/FAM or Forward Group 7 message is sent during call setup phase |
2000 |
20 seconds |
0x0E |
Await receipt of additional Information Message |
500 |
5 seconds |
0x10 |
Prolonged Call Setup |
18000 |
180 seconds |
0x11 |
Non-receipt of SAM/FAM in response to SAD |
2000 |
20 seconds |
0x12 |
Non-receipt of SAM or FAM in response to Send N Digits. |
|
Dynamic based on number of requested digits and Exchange Type. |
0x14 |
Hardware Blocking Timer |
12000 |
120 seconds |
0x15 |
TO-21 Call Clear Timer |
30000 |
300 seconds |
0x16 |
IAM-SAD maximum digit collection timer |
400 |
4 seconds --This value must be less than the value set for 0x11. |
0x17 |
Block Timer |
12000 |
120 seconds |