MTP3 SLTC   (0x0041)

Purpose

The Signaling Link Test Control (SLTC- 0x41) component is used to support the JT telecom standard for Signaling Route Test Control (SRTC).

JT MTP3 PPL Configuration Bytes

The table below shows the configuration bytes for JT MTP3 SLTC.

Byte

Description

Value

0x01

Variant (JT/NTT/DDI)

0x02 NTT/DDI

0x02

Disable non-adjacent received link verify

0x00

JT MTP3 PPL Events

The tables below show the JT PPL Event Requests and Event Indications for MTP3 SLTC.

Requests

Event ID

Event

0x01

Start Signaling Route Test Control (Request)

0x02

Result of Start Signaling Route Test Control (Indication)

Indications

Event ID

Event

0x01

Result of start SRTC

JT MTP3 PPL Timers

The table below shows the JT PPL Timer values for MTP3 SLTC.

Timer ID

Timer

Default Value (1000ms)

0x01

Supervision timer for Signal Route Test

10