Other MTP2 PPL Timers

Purpose

This section contains default settings for ANSI and ITU MTP2 PPL Timers, shown below by PPL component. The MTP2 timers are accurate to 10 ms.

MTP2 PPL Timers for other components (ITU)

PPL Component

Timer ID

Timer

Default Value

(10 ms)

CC (0x0021)

0x01

T5

10

IAC (0x0022)

0x01

T2

1150

0x02

T3

150

0x03

T4N

850

0x04

T4E

60

LSC (0x0023)

0x01

T1

4500

MTP2 PPL Timers for other components (ANSI)

PPL Component

Timer ID

Timer

Default Value

(10 ms)

CC

0x01

T5

10

IAC (0x0022)

0x01

T2

1150

0x02

T3

1150

0x03

T4N

230

0x04

T4E

60

LSC (0x0023)

0x01

T1

1300