SSUTR2 SPRC (0x0053)

Purpose

This section includes PPL Config Bytes, all PPL Events, and Timer information for the PPL Component SSUTR2 SPRC, a variant of TUP SPRC.

SSUTR2 SPRC Configuration Bytes

Byte

Description

Value

 

0x01

SIO subservice field

8

0x02

SIO service indicator

4

0x0A

Pause/Resume option

0

0x28

Number of samples, n, in moving average

100

0x29

Instantaneous Onset Threshold for Incoming Calls, 100 ms units

100 ms

0x2A

Moving Average Onset Threshold for Incoming Calls, 100 ms units

50 ms

0x2B

Abatement Threshold for Incoming Calls, 100 ms units

10 ms

0x2C

Number of samples, x, received before clearing congestion condition for Incoming Calls

10

0x2D

Instantaneous Onset Threshold for Outgoing Calls, 100 ms units

100 ms

0x2E

Moving Average Onset Threshold for Outgoing Calls, 100 ms units

50 ms

0x2F

Abatement Threshold for Outgoing Calls, 100 ms units

10 ms

0x30

Number of samples, x, received before clearing congestion condition for Outgoing Calls

10

SSUTR2 SPRC PPL Event Indications

Event ID

Event

0x01

Incoming Continuity Check successful

0x02

Incoming Continuity Check failure

0x03

Failure to receive FIU in response to call unsuccessful ECH

0x04

Stop ECH repeat after timeout

0x05

Stop FIU repeat after timeout

0x06

Continuity in incoming MIF

0x07

Outgoing continuity success

0x08

Outgoing continuity failure

SSUTR2 SPRC PPL Timers

Timer ID

Timer

Default Value (10ms)

0x01

Pause Timer Tick

400

0x02

Q probe timer

100