SUTR2 CRO (0x007C)

Purpose

This section includes PPL Config Bytes, all PPL Events, and Timer information for the PPL Component SSUTR2 CRO.

SSUTR2 CRO Configuration Bytes

Byte

Description

Value

 

0x0A

Recheck retry after failure (0-disabled, 1-Enabled)

1

0x0B

Number of retries

2

0x0F

FIU field count

0

SSUTR2 CRO PPL Event Indications

Event ID

Event

0x01

Retries exhausted after T8 expiry

0x02

Dual seizure, continuity recheck stopped

0x03

FIU repeat timer expiry, reset initiated

0x04

Error: Recheck attempt on non-idle circuit

0x05

LIG received indication

0x06

Continuity Recheck attempt successful after 1st retry

SSUTR2 CRO PPL Timers

Timer ID

Timer

Default Value (10ms)

0x01

TUP T9

1000

0x02

TUP T8

200

0x03

TUP T10

18000

0x04

Wait for LIG

1000

0x05

FIU repeat

6000