You are here: CSP Developer’s Guide: Common Channel Signaling > 13 V5.2 PPL Information > L3P BCC Protocol (0x8C)
Purpose
This section describes the PPL timers for L3P BCC Protocol.
L3P BCC Protocol PPL Timers (0x008C)
When specifying new timer values, remember that all PPL Timers are specified in 10 ms increments. For example, a PPL timer for 4 seconds is specified as 4000 (decimal, 400 x 10 ms = 4 seconds), which is the hexadecimal value of (0x190).
Timer ID |
Description |
Value (default) |
---|---|---|
0x01 |
Allocation Complete Wait |
1.5 seconds |
0x02 |
Deallocation Complete Wait |
2 seconds |
0x03 |
Deallocation Complete Wait |
2 seconds |
0x04 |
Audit Complete Wait |
1.5 seconds |
0x05 |
AN Fault Acknowledge Wait |
1.5 seconds |
0x06 |
Waiting for Datalink Connection Establish |
4 seconds |