You are here: CSP Developer’s Guide: Common Channel Signaling > 13 V5.2 PPL Information > L3P PSTN (0x91)
Purpose
L3P PSTN uses PPL configuration byte, event, and timer information.
Byte |
Description |
Values (* Default) |
---|---|---|
0x01 |
Send optional SIGNAL message (with steady |
* 0x00 = Send SIGNAL message |
0x02 |
Send optional SIGNAL message (with steady |
* 0x00 = Send SIGNAL message |
0x03 |
Deallocation option upon receiving Call Clearing message (send Channel Remove to BCC upon receiving on-hook, DISCONNECT or DISCONNECT COMPLETE) |
* 0x00 = Send Channel Remove to BCC |
0x04 |
Deallocation option upon sending |
* 0x00 = Send Channel Remove to BCC |
0x05 |
Call Collision Priority |
* 0x00 = Incoming call has priority |
0x06 |
Number of digits to receive before sending the SETUP Indication |
Default = 10 digits |
0x07 |
Request For Service Format |
* 0x03 = V5 Formatted ICB |
0x08 |
Specified the connected PPL state for PSTN |
* 0x04 |
0x09 |
Config. Byte offset to IE Table. First Byte is |
* 0x32 |
0x0A |
Calling Party Control |
0x00 |
0x0B |
Send L3 ESTABLISH Indication to L5 |
* 0x00 = Do not send PPL Event Indication |
0x0C |
Reserved |
|
0x0D |
Send L3 SIGNAL Indication to L5 |
* 0x00 = Do not send PPL Event Indication |
0x0E |
Send L3 STATUS Indication to L5 |
* 0x00 = Do not send PPL Event Indication |
0x0F |
Reserved |
|
0x10 |
Reserved |
|
0x11 |
Reserved |
|
0x12 |
Send L3 PROTOCOL PARAMETER |
* 0x00 = Do not send PPL Event Indication |
0x14 |
Send SIGNAL messages with digit info for Called Party |
* 0x00 = Do not send SIGNAL message |
0x15 |
Pulse Notification IE included in last SIGNAL message (Overlap Sending Option). |
* 0x00 = Include |
0x16 |
Stores Pulse Duration Type value Pulsed-Signal IE (FLASH Request) |
* 0x00 |
0x17 |
Stores Suppression Ind. value Pulsed-Signal IE (FLASH Request) |
* 0x00 |
0x18 |
Stores Acknowledge Request Ind. value for Pulsed-Signal IE (FLASH Request) |
* 0x00 |
0x1A |
Do not wait for SIGNAL messages with CLD (called) party number digits before sending SETUP Indication to L4 |
* 0x00 = Wait for digits |
0x1B |
Default Pulse Type to indicate a Switch Hook Flash |
* 0x76 = Register Recall |
0x20 |
Ringback Tone Option |
* 0x00 = Do not play Ringback * 0x00 = Do not play Ringback |
L3P/L5 Events
PPL Event Request (L5 to L3P) |
PPL Event Indication (L3P to L5) |
---|---|
0x0000 Reserved |
0x0000 Event Layer 3 Establish |
When specifying new timer values, remember that all PPL Timers are specified in 10 ms increments. For example, a PPL timer for 4 seconds is specified as 4000 (decimal, 400 x 10 ms = 4 seconds), which is the hexadecimal value of (0x190).
Timer ID |
Description |
Value (default) |
---|---|---|
0x01 |
Layer 3P BCC Response Wait |
8 seconds |
0x02 |
Signal (On-hook/Normal Polarity)/Disconnect Complete Wait |
4 seconds |
0x03 |
Layer 3 Digit Wait Timer |
4 seconds |
0x04 |
Layer 4 Clear Wait Timer |
4 seconds |
0x05 |
Layer 3 Establish Acknowledge Wait |
4 seconds |