You are here: CSP Developer’s Guide: Common Channel Signaling > 13 V5.2 PPL Information > L3P System Management Component (0x90)
L3P System Management Component (0x90)
Purpose
This section describes the PPL timers for L3P System Management Component.
L3P System Management Component PPL Timers (0x0090)
When specifying new timer values, remember that all PPL Timers are specified in 10 ms increments. For example, a PPL timer for 4 seconds is specified as 4000 (decimal, 400 x 10 ms = 4 seconds), which is the hexadecimal value of (0x190).
Timer ID |
Description |
Value (default) |
---|---|---|
0x01 |
Waiting for MDU Control (restart acknowledge) from all PSTN protocol State Machines |
100 seconds |
0x02 |
Waiting for MDU Control (restart complete) from Control Data Link |
120 seconds |
0x03 |
Waiting for MDL Establish Confirm or MDL Establish Indication from Control Data Link |
15 seconds |
0x04 |
Waiting for MDL Establish Confirm or MDL Establish Indication from Control Data Link |
60 seconds |
0x05 |
Waiting for MDL Establish Confirm or MDL Establish Indication from PSTN Data Link |
25 seconds |
0x06 |
Waiting for MDL Establish Confirm or MDL Establish Indication from Link Control Data Link |
15 seconds |
0x07 |
Waiting for MDL Establish Confirm or MDL Establish Indication from Link Control Data Link |
60 seconds |
0x08 |
Waiting for MDL Establish Confirm or MDL Establish Indication from BCC Data Link |
15 seconds |
0x09 |
Waiting for MDU Control (Unblock all relevant ports accepted) |
20 seconds |
0x0A |
Waiting for MDU Control (Unblock all relevant ports accepted) |
10 seconds |