DS3 Standby I/O Card - Model No. EXS-DIO-1200

Description

The DS3 Standby I/O card is used in conjunction with the DS3 Redundant I/O card to deliver N+1 redundancy. To support redundancy, you must use the supplied DS3 cable assemblies. These cables are supplied with the DS3 I/O card. See the DS3 Cable Assembly, Hardware Product Description.

Always use the supplied DS3 cable assemblies when connecting the DS3 I/O card and a DS3 Standby I/O card for redundancy or when connecting a DS3 I/O card directly to the network. Using other cables may damage the connectors on the DS3 I/O and Standby I/O cards and cause a failure or intermittent operation.

Grounding

When interfacing the DS3 I/O and Standby I/O cards with any electrical equipment with the DS3 cable assembly, proper wiring and grounding procedures must be followed. If not, ground loops mayn result which are dangerous and can result in physical harm as well as possible signal interference. See Chapter 4, Card Installation in the CSP Installation and Maintenance Guide.

Placement

The DS3 Standby I/O card resides in the rear card slots of a CSP 2090, CSP 2110 or CSP 2040 chassis. The DS3 Standby I/O card must reside in a slot numbered one greater than the Primary DS3 I/O card. For example if the Primary DS3 I/O card is in slot six, the standby DS3 I/O card must be in slot seven.

Configuration Information

The part number, serial number, model number, and revision are located on the back of the PC board.

Specifications

The DS3 Standby I/O card is designed to the following electrical, physical and environmental specifications.

Electrical

Specification

Supply Voltage, Vcc

5.00V

Supply Current, Vcc @ 5.0V

0.74A (typical)

Physical

Specification

Height

318.5 mm (12.54 in.)

Depth

105.2 mm (4.14 in.)

Width

19.7 mm (0.775 in.)

Environmental

Specification

Temperature - Storage

-40~C to 70~C (-40~F to 158~F)

Temperature - Operation

0~C to 50~C (32~F to 122~F)

Temperature Shock - Storage

-40~C to 70~C to -40~C (-40~F to 158~F to -40~F) @ 5~C/min.

Temperature Shock - Operation

0~C to 50~C (32~F to 122~F) @ 10~C/min.

Humidity - Operating

5% to 85%

Altitude

Up to 4000 m (13,123 ft.)

Compliance

The DS3 Standby I/O card complies with all relevant regulations from the following standards organizations and governing bodies.

Country/Standards Organization

Regulations

United States

 

FCC Part 15

CSA 60950-1-3

T1.102 Compliant

Canada

 

ICES 003

CSA 60950-1-3

NEBS

Level 3

European Union

CE Mark

G.703 Compliant

 

Related Products

The products related to the DS3 Standby I/O card are listed below.

Product

Model No.

DS3 Card

EXS-DS3-1000

DS3 I/O Card

EXS-DS3-1100

DS3 Cable Assy, 75 Ohm BNC Y (Part No. 64-0124-00)

Not Applicable

Controls and Indicators

The table below describes the LEDs as shown in the front view of the DS3 Standby I/O Card.

LED

Color/Status

Description

IN Service

Green

Indicates normal operation

Red

Indicates switchover (fault condition)

Board Status

Green

Indicates normal operation

 

Front and Side Views

The front and side views show the LEDs and connectors

.