IP Signaling Series 3 Card - Model No. EXS-SCS-1000

Description

The IP Signaling Series 3 card provides call server services for the Converged Services Platform (CSP) fully integrating switching and call processing applications. The IP Signaling Series 3 card enables the CSP to communicate with H.323 gateways in the call server network architecture.

Microprocessor

The IP Signaling Series 3 card is a Power PC-based controller card.

Placement

Each CSP 2090, CSP 2110 or CSP 2040 chassis accommodate IP Signaling Series 3 cards which reside in the front line card slots.

I/O

The CCS I/O Series 3 card is the I/O card for the IP Signaling Series 3 card.

Configuration Information

The part number, serial number, model number, and revision are located on the back of the board.

Specifications

The IP Signaling Series 3 card is designed to the following electrical, physical and environmental specifications.

Electrical

Specification

Supply Voltage, Vcc

5.00V

Supply Current, Vcc @ 5.0V

5.5A (typical)

Physical

Specification

Height

236.2 mm (9.3 in.)

Depth

317.5 mm (12.5 in.)

Width

19.7 mm (0.775 in.)

Environmental

Specification

Temperature - Storage

-40~C to 70~C (-40~F to 158~F)

Temperature - Operation

0~C to 50~C (32~F to 122~F)

Temperature Shock - Storage

-40~C to 70~C to -40~C (-40~F to 158~F to -40~F) @ 5~C/min.

Temperature Shock - Operation

0~C to 50~C (32~F to 122~F) @ 10~C/min.

Humidity - Operating

5% to 85%

Altitude

Up to 4000 m (13,123 ft.)

Compliance

The IP Signaling Series 3 card complies with all relevant regulations from the following standards organizations and governing bodies.

Country/Standards Organization

Regulations

United States

FCC Part 15

CSA 60950-1-3

Canada

ICES 003

CSA 60950-1-3

NEBS

Level 3

European Union

CE Mark

Related Products

The products related to the IP Signaling Series 3 card are listed below.

Product

Model No.

CCS I/O Series 3 Card

EXS-7IO-1300

 

Front View

The front view shows the LEDs, push button switches and Monitor connector.

Controls and Indicators

The table below describes the LEDs and push button switches as shown in the front view of the card.

LED

Color/Status

Description

Diag

Green

This LED is green except during a card reset when this LED goes out briefly. This LED is normally OFF.

Red

Redundancy has been configured.

Off

No diagnostics running

Status

Green

The card is connected to the system buses.

Red

The Stop push button has been pressed. The card is disconnected from the system buses.

Off

Not applicable.

Halt

Green

The CPU is running.

Red

The CPU has halted. This LED is red briefly during card reset.

Off

CPU hard reset

Power

Green

Good power

Off

Bad power

Push Buttons

Description

 

Stop

Removes card from the system buses. Always press the Stop push button before removing the card from the chassis.

Stop and S Reset together

Initiates a Hard Reset. The Flash and SDRAM are reset, as is the processor and all of its internal registers. A Hard Reset also occurs when the Watchdog times out twice in a row.

S Reset

Initiates a Soft Reset. The code running on the processor is reset, and the Flash is put into a read state.

DIP Switch SW1

The table below describes the DIP switch SW1 settings. The shading (asterisk* for html documents) indicates factory-installed settings.

Position

Setting

Function

1

ON*

Disables Debug 1 Mode

OFF

Enables Debug 1 Mode

2

ON*

The Monitor port setting is 19200 baud and is not selectable.

OFF

Reserved

3

ON*

Disables Debug 2 Mode

OFF

Enables Debug 2 Mode

4

ON*

Reserved, normally should be ON

OFF

Reserved

5

ON*

Disables Layer 5

OFF

Enables Layer 5

6

ON

Reserved

OFF*

API

7

ON*

Reserved, normally should be ON

OFF

Reserved

8

ON*

Reserved, normally should be ON

OFF

Reserved

Jumpers

The table below indicates the jumper settings.

Jumper

Setting

Description

JP1

Installed (default)

Factory use only

JP2

Installed (default)

Factory use only

JP3

Installed (default)

Factory use only

JP4

Not Installed (default)

Hardware Watchdog Timer enabled

JP5

Installed (default)

Factory use only

JP7

Not Installed (default)

Factory use only

JP8

Installed (default)

Factory use only

JP9

Installed (default)

Factory use only

JP10

Installed (default)

Factory use only

JP11

Installed (default)

Factory use only

Side View

The side view shows DIP switch SW1 and jumper JP4.