E1 PPL Component Information (0x0001)

Events

The events listed below are specific to the E1 PPL component.

Events 0-15 are Receive Line Signaling Events. They require an Event Data value for the Timer Filter. The data value is an index into the Generic Protocol Timer list that is configurable using the PPL Timer Configure message.

The default value for timers 1-45 are shown below in 10 millisecond units. Timers 46-100 are not used. See the default E1 PPL DSD for the default timers used for each event.

Table 3-1 E1 Events

0

RCV LINE SIG 0000

Receive CAS line signaling bits of a = 0, b = 0, c = 0, d=0.

Event Data: Index Into Generic Protocol Timer List for Filter Value

1

RCV LINE SIG 0001

Receive CAS line signaling bits of a = 0, b = 0, c = 0, d=1.

Event Data: Index Into Generic Protocol Timer List for Filter Value

2

RCV LINE SIG 0010

Receive CAS line signaling bits of a = 0, b = 0, c = 1, d=0.

Event Data: Index Into Generic Protocol Timer List for Filter Value

3

RCV LINE SIG 0011

Receive CAS line signaling bits of a = 0, b = 0, c = 1, d=1.

Event Data: Index Into Generic Protocol Timer List for Filter Value

4

RCV LINE SIG 0100

Receive CAS line signaling bits of a = 0, b = 1, c = 0, d=0.

Event Data: Index Into Generic Protocol Timer List for Filter Value

5

RCV LINE SIG 0101

Receive CAS line signaling bits of a = 0, b = 1, c = 0, d=1.

Event Data: Index Into Generic Protocol Timer List for Filter Value

6

RCV LINE SIG 0110

Receive CAS line signaling bits of a = 0, b = 1, c = 1, d=0.

Event Data: Index Into Generic Protocol Timer List for Filter Value

7

RCV LINE SIG 0111

Receive CAS line signaling bits of a = 0, b = 1, c = 1, d=1.

Event Data: Index Into Generic Protocol Timer List for Filter Value

8

RCV LINE SIG 1000

Receive CAS line signaling bits of a = 1, b = 0, c = 0, d=0.

Event Data: Index Into Generic Protocol Timer List for Filter Value

9

RCV LINE SIG 1001

Receive CAS line signaling bits of a = 1, b = 0, c = 0, d=1.

Event Data: Index Into Generic Protocol Timer List for Filter Value

10

RCV LINE SIG 1010

Receive CAS line signaling bits of a = 1, b = 0, c = 1, d=0.

Event Data: Index Into Generic Protocol Timer List for Filter Value

11

RCV LINE SIG 1011

Receive CAS line signaling bits of a = 1, b = 0, c = 1, d=1.

Event Data: Index Into Generic Protocol Timer List for Filter Value

12

RCV LINE SIG 1100

Receive CAS line signaling bits of a = 1, b = 1, c = 0, d=0.

Event Data: Index Into Generic Protocol Timer List for Filter Value

13

RCV LINE SIG 1101

Receive CAS line signaling bits of a = 1, b = 1, c = 0, d=1.

Event Data: Index Into Generic Protocol Timer List for Filter Value

14

RCV LINE SIG 1110

Receive CAS line signaling bits of a = 1, b = 1, c = 1, d=0.

Event Data: Index Into Generic Protocol Timer List for Filter Value

15

RCV LINE SIG 1111

Receive CAS line signaling bits of a = 1, b = 1, c = 1, d=1.

Event Data: Index Into Generic Protocol Timer List for Filter Value

16

FWD R2 SIG1

Receive multifrequency forward R2 signal 1.

17

FWD R2 SIG2

Receive multifrequency forward R2 signal 2.

18

FWD R2 SIG3

Receive multifrequency forward R2 signal 3.

19

FWD R2 SIG4

Receive multifrequency forward R2 signal 4.

20

FWD R2 SIG5

Receive multifrequency forward R2 signal 5.

21

FWD R2 SIG6

Receive multifrequency forward R2 signal 6.

22

FWD R2 SIG7

Receive multifrequency forward R2 signal 7.

23

FWD R2 SIG8

Receive multifrequency forward R2 signal 8.

24

FWD R2 SIG9

Receive multifrequency forward R2 signal 9.

25

FWD R2 SIG10

Receive multifrequency forward R2 signal 10.

26

FWD R2 SIG11

Receive multifrequency forward R2 signal 11.

27

FWD R2 SIG12

Receive multifrequency forward R2 signal 12.

28

FWD R2 SIG13

Receive multifrequency forward R2 signal 13.

29

FWD R2 SIG14

Receive multifrequency forward R2 signal 14.

30

FWD R2 SIG15

Receive multifrequency forward R2 signal 15.

31

BWD R2 SIG1

Receive multifrequency backward R2 signal 1.

32

BWD R2 SIG2

Receive multifrequency backward R2 signal 2.

33

BWD R2 SIG3

Receive multifrequency backward R2 signal 3.

34

BWD R2 SIG4

Receive multifrequency backward R2 signal 4.

35

BWD R2 SIG5

Receive multifrequency backward R2 signal 5.

36

BWD R2 SIG6

Receive multifrequency backward R2 signal 6.

37

BWD R2 SIG7

Receive multifrequency backward R2 signal 7.

38

BWD R2 SIG8

Receive multifrequency backward R2 signal 8.

39

BWD R2 SIG9

Receive multifrequency backward R2 signal 9.

40

BWD R2 SIG10

Receive multifrequency backward R2 signal 10.

41

BWD R2 SIG11

Receive multifrequency backward R2 signal 11.

42

BWD R2 SIG12

Receive multifrequency backward R2 signal 12.

43

BWD R2 SIG 13

Receive multifrequency backward R2 signal 13.

44

BWD R2 SIG 14

Receive multifrequency backward R2 signal 14.

45

BWD R2 SIG 15

Receive multifrequency backward R2 signal 15.

46

R2 COMP CYCLE COMPLETE

Generated upon R2 cycle completion when indicated by the Generate Call Processing Event of BWD R2 Compelled Signal with Cycle Completion.

50

L5 BUSY OUT

L4-initiated Busy Out event.

51

L5 BUSY OUT RELEASE

L4-initiated Release Busy Out event.

55

L4 CALL REQ

Outgoing call request generated by L4 when a Connect message is sent from L5 and the B party is in the idle state.

56

L4 ALERTING

L4 indication sent to the PPL on an incoming call when the destination is being rung.

57

L4 CONNECT

L4 indication sent to the PPL on an incoming call when the destination has answered.

58

L4 CLEAR REQ

L4 indication to release the call or L4 ACK to a L3 "Disconnect".

59

L4 BUSY OUT ACK

L4 ACK to L3 "Busy Out" message.

60

L4 PURGE

L4-initiated purge event.

61

L4 OUTSEIZE CONTROL

L4 Outseize Control message event.

62

L4 INSEIZE CONTROL

L4 Inseize Control message event.

66

DSP RESULT DIGITS

Generated upon detection of DTMF digits.

67

DSP RESULT FIRST-DIGIT TIMEOUT

Generated upon failure to detect DTMF digit.

68

DSP RESULT INTER-DIGIT TIMEOUT

Generated upon detecting DTMF inter-digit timeout.

69

DSP RESULT DIGITS COMPLETE TIMEOUT

Generated upon failure to detect a complete set of DTMF digits.

70

DSP RESULT OUTPULSE COMPLETE

Generated upon DTMF digit outpulsing completion.

71

L3PPLevDSP_RESULT_CP_RESUL.

Generated when DSP reports a call progress analysis result.

72

DSP Result Dialtone Detected

Generated upon detection of dial tone.

80

DSP Announcement Start

Generated by the beginning of a recorded announcement.

81

DSP Announcement Complete

Generated by the completion of a recorded announcement.

Table 3-2 E1 PPL Timers

Timer Number

Description

Default Value

(in 10 ms units)

1

(S19) Incoming Layer 4 busy out Acknowledge wait

400

2

(S2) Incoming Stage 1 FWD digit receive wait

2,000

3

(S3) Incoming Stage 2 FWD digit receive wait

2,000

4

(S4) Incoming Stage 3 FWD digit receive wait

2,000

5

(S5) Incoming Stage 4 FWD digit receive wait

2,000

6

(S13) Layer 4 Connect wait

24,000

7

(S14) Layer 4 Clear wait

400

8

(S21) Clear Forward (idle line signal) wait

1,500

9

(S3) Incoming Stage 2 Initial FWD digit receive wait

2,000

10

(S2) Incoming Stage 1 Initial FWD digit receive wait

2,000

11

(S5) Incoming Stage 4 Initial FWD digital receive wait

2,000

12

(S4) Incoming Stage 3 Initial FWD digit receive wait

2,000

13

(S15) Layer 3 Circuit Release wait

10

14

(S18) Layer 3 Circuit Release wait

10

15

(S6) Host Control wait

6,000

16

(S13) Layer 4 Connect wait

24,000

17

(S29) Seize Acknowledge wait

400

18

(S31) After detecting glare time to wait before transmitting idle signal

10

19

(S32) Time to wait before looking for idle line signal after transmitting idle signal when glare detected

10

20

(S39) Outgoing Stage 1 BWD R2 signal wait

1,500

21

(S39) Outgoing Stage 1 Initial BWD R2 signal wait

1,500

22

(S41) Outgoing Stage 2 BWD R2 signal wait

1,500

23

(S41) Outgoing Stage 2 Initial BWD R2 signal wait

1,500

24

(S43) Outgoing Stage 3 BWD R2 signal wait

1,500

25

(S43) Outgoing Stage 3 Initial BWD R2 signal wait

1,500

26

(S45) Outgoing Stage 4 BWD R2 signal wait

1,500

27

(S45) Outgoing Stage 4 Initial BWD R2 signal wait

1,500

28

(S46) Outgoing Host Control wait

24,000

29

(S50) Outgoing Layer 4 Clear wait

400

30

(S49) Outgoing idle line signal wait

12,000

31

(S50) Outgoing idle line signal wait (after glare detected)

12,000

32

(S24) Host Control wait

24,000

33

(S33) Time to wait for Clear Forward after glare detected

1,000

34

Receive line signaling filter

4

35

Not Used

N/A

36

(S6, S24) Incoming BWD R2 Cycle Complete Event wait

400

37

Not Used

N/A

38

(S10) Time to wait for idle line signaling after invalid line signal detected while receiving FWD R2 digits

2,000

39

(S22) Layer 3 Clear Forward wait

300

40

(S39) Outgoing Stage 1 BWD A signal wait after sending all of stage 1 FWD digits

2,000

41

(S2, S3, S4, S5) FWD R2 digit receive wait when String Collection Data field in Inpulsing Parameters Configure is set to 0xFF

144

42

Not Used

N/A

43

R2 Cycle Complete Event wait

200

44

Time to wait for Call Progress Analysis Result

1,500

45

(S43) Time to wait for next BWD R2 signal when stage 3 digits have been outpulsed

2,000