Response Status Values

Hex ID

Name

Description as necessary

00 00-
00 0F

These values differ depending on the message that returns them.
Please refer to the specific message for the response status values.

00 10

Positive Acknowledgment (ACK)

 

The message was successfully processed, and any required actions were successfully completed.

00 11

Bad Checksum

 

The message checksum does not match the checksum calculated by the system. An error must exist or a field must be missing.

00 12

Invalid Logical Span ID

 

A field reserved for a logical span ID contains a number larger than the capacity of the switching matrix.

00 13

Invalid Channel Number

 

A field reserved for a channel number is outside the range of 0–30 for E1 or 0–23 for T1. For E1, you can reference channel 30 only if the channel is configured for CCS, with the E1 Span Configure message.

00 14

Message Invalid for Current Matrix State

The Matrix Controller is not in a state to accept this message.

00 15

Negative Acknowledgment (NACK)

Message could not be successfully processed.

00 16

Invalid Address Range

The address range specified in a block configuration message is
not valid.

00 17

Invalid Data Type

Returned in response to a message with invalid data parameters.

00 18

Invalid Channel B State

 

Channel B is in an invalid state for the action required. The

More Status field indicates the state.

NOTE: This does not pertain to ISDN B channels.

00 19

Trunk Status Dead

 

One of the parties involved in a Call Processing message is associated with a dead line.

00 1A

Inseize Failure

 

Inseize could not be successfully completed
(for example, distant end signaling error).

00 1B

Outseize Failure, No Acknowledgment

 

Outseize failed because acknowledgment signaling conditions were never met (for example, a channel of E&M wink start trunk did not receive a wink).

00 1C

Outseize Failure, Glare

Outseize attempted on trunk involved in inseizure processing.

00 1D

Invalid Channel A State or Invalid PPL Event

Channel A is in an invalid state for the action required. The

Status field indicates the state of Channel A.

A PPL component has received an invalid event for the current

PPL state.

00 1E

Memory Allocation Failure

Channel configuration change failed due to lack of available memory.

00 1F

Invalid Group Number

Reserved for future use.

00 20

Invalid Action Value

Invalid decision parameter action value was received.

00 21

Invalid Time

The value entered for the time is not valid.

00 22

First Outseize Instruction Not A Seize

 

The first instruction in an Outseize Control message must be a Seize if the channel is idle.

00 23

Outseize "Seize" Instruction Not Allowed

 

This response is returned if one of the following occurs:

An Outseize Instruction List Configure message is sent with a Seize instruction (a Seize instruction cannot be preprogrammed).

An Outseize Control message with a Seize instruction is sent when one has been sent previously and the call is still active.

00 24

Outseize Failed Due To No Answer

Outseize failed due to no answer from the distant end.

00 25

Invalid Encoding Format

One of the following is invalid: the encoding format of RAN or the encoding format in a Conference Create message.

00 26

Invalid Conference Size

 

Sent in response to a host-initiated Conference Create message, when the conference size indicated is less than 2 or greater than the maximum number of channels allowed to be conferenced together.

00 27

DSP Not Configured for Requested Function

No DSPs are configured for the function requested by the host (for example, configuration for service).

00 28

DSP Resources Not Available

 

No DSP resources are currently available for the requested DSP function. Applies to DSP functions which are not managed as shared resources, for example, Conference Create.

00 29

Invalid Conference Output Option

 

Conference output option indicated in the Conference Create message is not valid.

00 2A

Invalid Conference ID

 

Conference ID sent by the host is not associated with any conferences previously established through the Conference Create message.

00 2B

Conference Create Failure

 

Conference creation failed while the conference was establishing (for example, the MFDSP card was removed).

00 2C

Conference Establishing

 

Returned in a Delete Conference, Connect to Conference, or Connect 1-Way to Conference message if the conference associated with the conference ID is in the process of being created.

00 2D

Incompatible PCM Encoding for Conference

 

Returned in a Connect to Conference and Connect 1-Way to Conference message when the channel encoding format doesn’t match that of the conference (for example, A-law encoded channel connected to a µ-law encoded conference).

00 2E

Conference Size Exceeded

 

Returned in a Connect to Conference message when the conference size has been exceeded.

00 2F

Maximum Broadcast Number Exceeded

 

Returned in a Connect 1-Way or Connect 1-Way to Conference message when the number of 1-Way broadcasts exceeds the maximum allowed.

00 30

DSP Resource Already Allocated

 

Returned in a Collect Digit String or DSP Service Request message if digit collection is already active on the specified channel.

00 31

Channel Violation

 

Returned if an Matrix Controller 1000 Series 3 card is being used in a system with more than 1,024 channels.

00 32

Channels A and B Already Connected

 

A connect request has been sent for two channels which are already connected.

00 33

SS7 Configuration Error

Possible scenarios regarding virtual spans:

1. Configuring virtual CICs on remote nodes using an SS7 PQ card in the server node.

2. Configuring virtual CICs on a virtual VOCC card (type 0x80) using either an SS7 PQ card or an HP card.

3. Configuring virtual CICs beyond five virtual T-ONE cards or four virtual E-ONE cards on the server node using an SS7 PQ card.

00 34

Ring Timeslot Inaccessible

Remote timeslot is not accessible from this node. Check Excel platform hardware.

00 35

Invalid Logical Ring ID

00 36

Unassigned Ring

00 37

Ring Already Assigned

00 38

Invalid Ring State

00 39

No Bandwidth Available

00 3D

Invalid ICB Data

 

An information control block has invalid length or count field, or the data within the ICB is invalid.

00 3E

ISDN Congestion

 

00 40

SRecord Invalid

Download aborted due to invalid SRecord.

00 41

Out of Sequence, Restart Download

Restart download due to sequence problem.

00 42

BRecord Invalid

BRecord not accepted due to invalid value.

00 43

Node Not Ready

 

A valid Logical Node ID has not been assigned (therefore, Polls cannot be requested) or the Excel platform is not in a valid state for the requested action (such as Download Begin during Boot State).

00 44

No Download Begin Message Received

 

A Download SRecord or Download BRecord message was sent without a proceeding Download Begin SRecord or Download Begin BRecord message.

00 45

Invalid Download

 

Sent in response to a Download Complete message when the download does not validate due to an incorrect checksum.

00 47

Invalid Ring Loop Timing

00 4B

RTP Port in Use

00 54

SS7 Invalid SCCP TCAP Parameter

 

An SS7 SCCP TCAP configuration attempt specified an invalid SS7 SCCP TCAP parameter.

00 55

SS7 Invalid SCCP TCAP Configuration Parameter

 

An SS7 SCCP TCAP configuration attempt specified an invalid SS7 SCCP TCAP configuration parameter.

A Excel platform returns this indication when a host queries for a configuration parameter using the message, SS7 SCCP/TCAP Query (0x78).

00 56

System Busy Condition on Remote Node

00 57

Conferencing Disabled

00 58

Invalid Remote Timeslot for Connect 1-way Forced

B address is not a valid remote timeslot.

00 59

Outseize Failure, Blocked

00 5A

DS3 Out of Service

 

An attempt is being made to bring one of the DS3’s spans in service but the DS3 is out of service

00 5B

DS3 Offset Out of Range

DS3 Offset is outside the valid range 0-27

00 5D

Invalid Data Value

Invalid data or data out of range

00 5E

DS3 In Service

An attempt is being made to loop back to a DS3, but the DS3 is in service

00 5F

Invalid Resource Attribute

00 60

Outseize Failure, Guard Timing

 

Returned when the connection terminating party is in the guard state allowing for inseizures only.

00 61

Invalid Slot

The slot specified is not valid for the message sent.

00 62

Invalid Span Offset

 

Field reserved for span offset is outside the valid range for the line card (0–1 for 2-span, 0–3 for 4-span, 0–7 for 8-span).

00 63

Unassigned Span

 

The host has not yet assigned the specified Logical Span ID to a physical span.

00 64

Unassigned Span A

 

The host has not yet assigned that span number to a hardware location. If two span/channels exist in message, the first span address is unassigned.

00 65

Unassigned Span B

 

The host has not yet assigned that span number to a hardware location. If two span/channels exist in message, the second span address is unassigned.

00 66

Outseize Failure, Busied Out

Returned when connection terminating party is busied out.

00 67

Channel B Out of Service

Returned when connection terminating party is out of service due to a span alarm condition, is disabled, or both. Also returned if terminating party is going through error recovery or if no release of the distant end is detected.

00 68

Channel B Not Idle

 

Returned when the connection terminating party is currently involved in call setup or teardown with another call.

00 69

Span Already Assigned

Span selected to be assigned is already assigned.

00 6A

Span Offset Not Available

A span has been previously assigned to that slot and offset.

00 6B

Span Providing Loop Timing

 

Span selected to be unassigned has been selected as a loop timing source.

00 6C

Framing Error

An incorrect framing type was specified.

00 6D

Zero Suppression Error

An incorrect zero suppression type was specified.

00 6E

invalid Cable Length

An invalid cable length was specified.

00 6F

Card Out of Service

The card in the slot specified is not in service.

00 70

Single Matrix Out of Service Attempt

A single matrix cannot be taken out of service.

00 71

Channel Out of Service

One or more of the specified channels is out of service.

00 72

Span In Service

The span specified is in service.

00 73

Span Out of Service

The span specified is out of service.

00 74

Invalid Card Type

Incorrect card type for attempted operation.

00 75

Invalid Entity

The entity is out of range.

00 76

DSP SIMM in Service

The SIMM specified is in service.

00 77

Invalid DSP SIMM Value

The value specified for SIMM is invalid.

00 78

Invalid DSP Function Type

The type specified for SIMM is invalid.

00 79

Invalid DSP SIMM Configuration

The configuration specified for SIMM is invalid.

00 7A

Deletion of VRAS SIMM In Progress

 

An attempt has been made to download a recorded announcement to a SIMM while the SIMM is in the process of being deleted.

00 7B

Another Announcement Download is in Progress

 

An unsuccessful attempt has been made to download a recorded announcement while another recorded announcement download is in progress.

00 7C

No Recorded Announcement Download Initiate Message Received

A Recorded Announcement Download message has been sent without a prior Recorded Announcement Download Initiate message sent.

00 7D

CCS Redundant I/O Card Not Available

ISDN or SS7 card in a redundant system is missing or unavailable.

00 7E

RAN Download to Out of Service DSP

 

An attempt was made to download a recorded announcement to a DSP that is out of service.

00 7F

Software module still locked.

 

This value is returned when attempting to configure a locked module for which no product license has been downloaded. The value can be received only with the SS7 Signaling Stack Configure (0x5C) and SS7 CIC Configure (0x6A) messages.

00 80

Partial Dial Condition

The receive inter-digit timer has expired.

00 81

Permanent Signal Condition

The 1st receive digit timer has expired.

00 82

Failure to Receive Wink 1

The maximum Receive Wink 1 detection timer has expired.

00 83

Failure to Receive Wink 2

The maximum Receive Wink 2 detection timer has expired.

00 84

Failure to Receive Wink 3

The maximum Receive Wink 3 detection timer has expired.

00 85

Failure to Receive Wink 4

The maximum Receive Wink 4 detection timer has expired

00 86

Failure to Receive Wink 5

The maximum Receive Wink 5 detection timer has expired.

00 87

Failure to Receive Wink 6

The maximum Receive Wink 6 detection timer has expired

00 88

Failure to Receive Wink 7

The maximum Receive Wink 7 detection timer has expired.

00 89

Failure to Receive Wink 8

The maximum Receive Wink 8 detection timer has expired.

00 8A

No SIMM In Service For Requested Function

There is no SIMM currently in service and configured for tone generation or VRAS.

00 8B

No Outpulsing Data Available

Outpulse data is not available for the stage indicated.

This response is also returned when connecting to an idle SS7 channel.

00 8C

No Action ICBs in Message

An Outseize Control or Inseize Control message was sent without any action ICBs included.

00 8D

No Data ICBs in Message

An Outseize Control message was sent without a required data ICB included.

00 8E

Wink Tolerance Exceeded

Given incoming wink exceeded maximum allowed duration.

00 8F

Failure to Detect Off-hook

An ANI request off-hook was not detected within the detection interval.

00 90

Failure to Detect Dialtone

Dialtone not detected within detection interval.

00 91

Inpulsed Stage Not Collected

Collection of given stage of incoming digits not indicated.

00 92

Inpulsing Complete Timeout

Time for complete incoming digit string collection for a given stage exceeded maximum time allowed.

00 93

Invalid Inpulsed Source Span/Channel

An invalid span/channel is indicated as the inpulsing channel.

00 94

No Valid Inpulsed Data to Outpulse

An Outpulse Stage N with Previously Inpulsed Digits instruction was initiated, however, the specified inpulsing has not occurred or has failed.

00 96

Invalid Configuration Request for Span

Specified configuration request for span is invalid.

00 98

No ULC Module

ULC module is missing.

00 99

Invalid Configuration Request

Configuration request is invalid.

00 9A

Invalid Command for Card Type, Span, or Channel

Message does not apply to this card, span, or channel.

00 9B

Illegal D Channel Function

For ISDN D channel call control administration only.

00 9C

Invalid ISDN D Channel

ISDN PRI D channel is not valid.

00 9D

Invalid ISDN B Channel

ISDN PRI B channel is not valid.

00 9E

Invalid ISDN Facility

ISDN facility is invalid.

00 9F

Invalid Value for Entity

The value specified for entity is invalid.

00 A0

SIMM Not Present

SIMM specified is not present.

00 A1

D Channel Assigned

A D channel is assigned on span ID selected.

00 A2

Called Party Mandatory for ISDN Setup

The called party digits are mandatory instruction elements over ISDN PRI.

00 A3

Card Not Ready for Configuration

The card is not in a valid state to accept configuration data.

00 A4

ISDN D Channel Exceeds Maximum

The ISDN card specified can not be configured for another D channel.
Check the card’s address mode.

00 A5

Invalid Option for Protocol

Protocol assigned to channel in ranges does not allow for the function the host is trying to perform.

00 A6

PPL Table Size Exceeds Max

Size of table host wishes to download is too large.

00 A7

PPL Table Already Exists

Table ID already in use.

00 A8

PPL Table Does Not Exist

Table ID referenced does not yet exist.

00 A9

PPL Table Does Not Validate

The table the host has downloaded does not validate. Further information can be found in Byte and Entity fields of message responding to this error.

00 AA

Insufficient Hardware

 

The function the host is trying to perform can not be performed because the hardware needed is not present.

00 AB

PPL Table Part of Protocol

 

Error occurred trying to delete a Primitive Table or State/Event Table. The protocol that the table is associated with must be deleted first.

00 AC

Invalid Command for ISDN Facility

The command for the ISDN facility was not valid.

00 AD

DSP Resource Inconsistency

 

Returned in a Collect Digit String or DSP Service Request message if digit collection is already active on the specified channel. Also returned when the host attempts to configure two transmitters on one card at the same time.

00 AE

Hardware Not Configured for DSP Function

 

The DSP resource management software has been requested to provide a DSP resource which does not exist. Please check DSP configurations of DSP card by sending a Card Status Query message.

00 AF

PPL Layer Forward Signal Timeout

 

Forward R2 Signal has not been detected within the maximum amount of time allowed.

00 B0

PPL Layer Backward Signal Timeout

 

Backward R2 Signal has not been detected within the maximum amount of time allowed.

00 B1

PPL Layer Premature Answer

Answer was detected on an outgoing call before call setup completion.

00 B2

PPL Layer Congestion Received

Backward R2 Congestion Signal has been detected.

00 B3

System Table in Use

 

System software is using the table you are trying to modify/create. Please wait a few seconds and try again.

00 B4

Line Card Response To Matrix Timeout

 

The matrix timed-out waiting for a response from a line card. Check configuration for channel ranges that span more than two cards.

00 B5

CPA Member Exceeds Maximum For Class

 

The maximum number of call progress analysis patterns which can be included in a class has been reached.

00 B6

CPA Pattern Exceeds Maximum

 

The maximum amount of call progress analysis patterns supported by the system has been reached.

00 B7

CPA Tone Group Exceeds Maximum

 

The maximum amount of call progress analysis tone groups supported by the system has been reached.

00 B8

Invalid Pattern ID

An invalid pattern ID has been specified for call progress analysis.

00 B9

Invalid Interval Descriptor Count

 

An invalid interval descriptor count has been specified for call progress analysis.

00 BA

CPA Classes Exceeds Maximum

 

The maximum amount of call progress analysis classes supported by the system has been reached.

00 BB

Invalid CPA Class

 

An invalid call progress analysis class was specified in a configuration message.

00 BC

Invalid Data Found at Byte N

 

The message became invalid because of data found at byte offset N. See the LSB of the Status field of the message for the byte offset where data became invalid.

00 BD

Invalid Table Type

The table type specified is invalid.

00 BE

Invalid Table ID

The table ID specified is invalid.

00 BF

ISDN Response Wait Timeout

 

ISDN-initiated message timed-out; waiting for a response from the network (for example, Register with no Release Complete).

00 C0

Action Denied

Action request denied.

00 C1

Action Rejected

Action request rejected.

00 C2

Slot Assigned As Standby

The slot number is assigned as a standby slot.

00 C3

Slot Not Assigned As Standby

The slot number is not assigned as a standby slot.

00 C4

Standby I/O Relay State Mismatch

 

The states of the relays of the I/O cards specified do not match (relays on one are enabled; relays on the other are disabled).

00 C5

Incompatible Line Card Types

The line cards specified are not compatible.

00 C6

Redundant I/O Cards Not Present

Redundant I/O cards are not present in one or more of the slots specified.

00 C7

Line Card Switchover Already Completed

The Line Card Switchover requested has already been completed.

00 C8

Invalid SIMM Type

Trying to perform VRAS functions on a non-VRAS SIMM.

00 C9

Invalid Recorded Announcement ID

 

The recorded announcement ID is not in the allowable range or the host has requested a recorded announcement ID that does not exist in the system.

Allowed Range

MFDSP/DSP-ONE: 0 - 4,095

DSP Series 2: Not Applicable

00 CA

Recorded Announcement Already Exists

 

The host has attempted to download an announcement using a recorded announcement ID that is already stored in the system.

00 CB

Insufficient Memory on VRAS SIMM

Not enough memory to store the specified recorded announcement.

00 CC

Maximum Recorded Announcement Limit Reached on VRAS SIMM

The host has attempted to download more than the maximum allowed recorded announcements to a particular VRAS SIMM.

MFDSP - 300

DSP-ONE - 2,048

DSP Series 2 - Does Not Apply

00 CD

Invalid IE Length

The host has sent an information element (IE) in an ICB with an incorrect length.

00 CE

Invalid IE Count

The host has sent an ICB with an incorrect IE Count value.

00 CF

Invalid Component Type

The host has sent an ICB with an incorrect component type.

00 D0

ISDN D Channel Switchover Timed Out

The D channel switchover could not be completed due to timer expiration.

00 D1

Invalid ISDN Connection Endpoint Identifier

A valid Connection Endpoint Identifier could not be found for the addressed D channel.

00 D2

Invalid AIB

The address information block (AIB) is not in the proper format, or it addresses an invalid PPL state machine or channel.

00 D3

Invalid Protocol ID

A protocol ID specified in a PPL message is invalid.

00 D5

Channel Already In Service

Applies to ISDN and SS7 only. Indicates that you attempted to either assign or de-assign a protocol to a channel that is in service.

00 D6

Invalid Command For Trunk Front End

An invalid command was sent from the host for a trunk front end.

00 D7

End Of PPL Audit Data

 

The end of the PPL auditing data has been reached. There are no more PPL auditing blocks in the PPL auditing logs.

00 D8

Invalid SS7 Signaling Stack ID (0–3)

 

A signaling stack was specified that either:

Was greater than the allowed values (0–3), or

Did not match the signaling stack for the primary resource

00 D9

SS7 Signaling Stack Already Configured

 

An attempt was made to configure an SS7 signaling stack that is already configured.

00 DA

Invalid SS7 Module Count

 

An attempt was made to configure an SS7 signaling stack with an invalid number of modules. The module count must be 3.

00 DB

Duplicated SS7 Module

 

An SS7 signaling stack configuration attempt specified the same SS7 model more than once.

00 DC

Unsupported SS7 Module Variant

 

An SS7 signaling stack configuration attempt specified an unsupported SS7 module variant.

00 DE

Invalid SS7 Module Type

 

An SS7 signaling stack configuration attempt specified an invalid SS7 module type.

00 DF

Invalid SS7 Signaling Stack Configuration

An SS7 signaling stack configuration attempt could not be interpreted correctly.

00 E0

SS7 Signaling Stack Not Configured

 

An SS7 signaling stack configuration attempt specified a signaling stack ID that is not configured.

00 E1

Invalid SS7 Signaling Link ID

 

An invalid SS7 signaling link ID was specified that was either:

Too large for the SS7 card model, or

An attempt was made to de-configure a link that is not configured.

00 E2

Invalid SS7 Signaling Link Set ID

 

An invalid SS7 signaling link set ID was specified. Valid Link Set IDs are 0 to 35.

00 E3

SS7 Signaling Link Set Not Configured

 

An SS7 configuration attempt specified a signaling link set that is not configured.

00 E4

SS7 Signaling Link Already Configured

An SS7 configuration attempt expected the specified SS7 signaling link either:

Was not configured, or

Did not have configured SS7 signaling links

00 E5

Invalid SS7 SLC

 

An SS7 configuration attempt specified an invalid SLC. Valid SLC codes are 0 to 15.

00 E6

SS7 Signaling Link Set Already Configured

 

An SS7 configuration attempt expected either:

The specified SS7 signaling set was not configured, or

The specified SS7 signaling stack had no configured SS7 signaling link sets

00 E7

SS7 APC Already Configured

 

An SS7 configuration attempt specified an adjacent point code (APC) that has already been associated with another link set. All links within a SS7 signaling stack that link to an adjacent signalling point must belong to a single link set.

00 E8

Invalid SS7 Signaling Link Data Rate

 

An SS7 configuration attempt specified an invalid signaling link data rate. Valid data rates are 64 Kbps (0) and 56 Kbps (1).

00 E9

SS7 SLC Already Configured

 

An SS7 configuration attempt specified an SLC that has already been assigned to another link within the same link set.

00 EA

Invalid DCE-DTE Configuration

 

An SS7 configuration attempt specified an invalid DCE-DTE configuration.

00 EB

SS7 Signaling Route Already Configured

 

One of the following is true:

An SS7 signaling route configuration specified a route ID that already exists, or

An SS7 signaling route configuration attempted to de-configure a destination for which CICs are still configured.

An SS7 signaling linkset configuration attempted to de-configure a linkset for which routes are still configured.

00 EC

Invalid SS7 Signaling Route Mode Configuration

 

An SS7 Signaling Route Configure message failed due to one of the following:

It specified a previously configured destination ID, but the specified stack ID or DPC did not match the previously configured destination ID.

It used a destination ID that was not previously configured, but a previously configured destination ID for the signaling stack has a matching DPC.

It reused the same link set to the same DPC (Route duplication)

 

An SS7 Signaling Route Query message failed due to one of the following:

An invalid destination ID (valid IDs are 0 to 63)

An invalid route ID (valid IDs are 0 to 254)

Either the specified route ID or destination ID is not configured to the specified stack ID

The specified destination ID and route ID are inconsistent

00 ED

No SS7 Signaling Route Entry Available

 

An SS7 Signaling Route Configure message was received and there were no unused route table entries. Excel supports up to 20 routes per stack.

00 EE

SS7 Signaling Destination Not Configured

 

An SS7 configuration attempt specified a destination in the SS7 signaling stack that was not previously configured.

00 EF

No SS7 Signaling DPC Entry Available

 

An SS7 DPC-CIC Configure message was received specifying a DPC when no more DPC table space is available. The system allows for one DPC per span. If you try to configure more than 128 CIC groups on one system, you will get this message.

00 F0

CCS Redundancy Already Configured

 

A CCS redundancy configuration attempt specified a primary and/or secondary slot that has previously been configured.

00 F1

CCS Redundancy Not Configured

 

A CCS redundancy configuration or query message was received before a CCS Redundancy Configure message was received.

00 F2

CCS Redundancy: Not A Primary Slot

 

The CCS Redundancy Configure message attempted to reference the secondary card in a CCS redundant pair. You must reference the primary card only.

00 F3

Channel Already an SS7 CIC

 

An SS7 CIC Configure message was received that specified a CIC (or group thereof) that has been previously configured for the same channel.

00 F4

Primary SS7 Slot Same As Secondary Slot

 

An CCS Redundancy Configure message was received specifying the same slot as the primary and secondary slot.

00 F5

No SS7 Signaling Links Configured

 

An SS7 configuration attempt specified one of the following:

An SS7 signaling link that is not configured

An SS7 signaling link set that has no configured SS7 signaling links

00 F6

No SS7 Signaling Routes Configured

 

An SS7 configuration attempt specified a destination ID or route ID that was not configured.

00 F7

SS7 DPC-CIC Already Configured

 

An SS7 DPC-CIC Configure message was received that specified a DPC-CIC (or group thereof) that has been previously configured for the same signaling stack.

00 F8

No SS7 Configuration Entity Available

 

An SS7 signaling route configuration attempt failed because it specified an entity (destination ID or route ID) that was not currently configured, but may have been configured previously.

An SS7 DPC-CIC configuration attempt failed because no free DPC-CIC resources were available.

00 F9

Invalid Number of SS7 ISUP Parameters

 

An SS7 ISUP Message Configure message was sent with an invalid number of parameters.

00 FA

Invalid SS7 ISUP Message Type

 

An SS7 ISUP Message Configure message was sent with an illegal Message Configuration Entry value.

00 FB

Node Already Exists

 

The Assign Logical Node ID message failed because node is already assigned.

00 FC

Invalid Node ID

 

A node ID is invalid because it met one of the following conditions:

Specified node ID is greater than maximum value of 31 (0x1F).

Specified node ID is greater than maximum value allowed when Excel platform conferencing is enabled.

00 FD

Node ID Not Configured

 

Assignment of spans failed because node is not yet assigned. When sending SS7 CIC Configure (0x6A) over Excel platform, this response value indicates the Ethernet is not available to the SS7 I/O card and you should check the connection.

00 FE

Maximum Number of Redundant Objects Reached

11 11

Invalid Module

Module specified is invalid (Valid range is 0x00 - 0x03)

11 12

Module Not Present

Module specified is not present

11 13

Module Not Ready

Module is not in a state to receive messages

12 00

SIP Common Error

12 01

Invalid IP Signaling Series 3 Card ID

Invalid IP Signaling Series 3 Card ID used, or ID is out of the valid range

User Not Found

For SIP, used in Route Control and PPL Event Request messages.

12 02

Invalid TLV tag

12 03

MatrixInternal error

Invalid PPL event

For SIP, used in Route Control and PPL Event Request messages.

12 04

Configuration Not Completed

Invalid Data

For SIP, used in Route Control and PPL Event Request messages.

12 05

Invalid Query Type

12 06

IP Signaling Series 3Card ID already configured

12 07

Invalid Type

12 08

Invalid State

Trying to set an invalid service state or the Matrixis already in this state

For SIP, used in Route Control and PPL Event Request messages.

12 09

Invalid IPDC Usage option

Trying to set an invalid IPDC usage or the option is out of range

12 0A

Invalid IP Signaling Series 3 Card interface support

Trying to set an invalid IP Signaling Series 3 Card interface support

12 0B

Invalid Base Value

Trying to set an invalid base value for channels and spans

12 0C

IP Signaling Series 3 Card ID not configured

Response to Query

12 0D

IP Signaling Series 3 Card not in service

Response to Query

13 00

SIP Common Error

For SIP, used in Route Control and PPL Event Request messages.

13 01

User Not Found

For SIP, used in Route Control and PPL Event Request messages.

13 02

Invalid Call Handle

For SIP, used in Route Control and PPL Event Request messages.

13 03

Invalid PPL Event

For SIP, used in Route Control and PPL Event Request messages.

13 04

Invalid Data

For SIP, used in Route Control and PPL Event Request messages.

13 05

Network Error

Remote end rejected the message. For SIP, used in Route Control and PPL Event Request messages.

13 06

Timer Expired

For SIP, used in Route Control and PPL Event Request messages.

13 07

No more PPL state machines available

For SIP, used in Route Control and PPL Event Request messages.

13 08

Invalid State

For SIP, used in Route Control and PPL Event Request messages.

13 09

Invalid Time Slot

For SIP, used in Route Control and PPL Event Request messages.

13 0A

VDAC Rejected

For SIP, used in Route Control and PPL Event Request messages.

13 0B

Authentication Failed

For SIP, used in Route Control and PPL Event Request messages.

14 01

Invalid Config Object Type

14 02

Invalid or Out-of-Range Config Instance ID for the IP Signaling Series 3 Card

14 03

Invalid Query Type

14 04

Invalid TLV tag

14 05

IP Signaling Series 3 Card Internal Error

14 06

Invalid TLV value

14 07

Invalid ICB

14 08

Configuration was not completed

14 09

IP Signaling Series 3 Card ID already created

14 0A

Invalid State

 

Trying to set an invalid service state
or the call server is already in this state

14 0B

Matrix Controller ID already created

14 0C

Invalid Matrix Controller ID

14 0D

Invalid Slot Number

14 0E

IP Signaling Series 3 Card is not configured

17 01

Invalided DSP Number

Used in messages Service State Configure, DSP SIMM Configure

17 02

File ID Not Found

Used in message DSP Cache Modify.

17 03

No Active Playback/Record Session

Used in messages Play File Modify, Play File Stop, Record File Modify,
Record File Stop

17 04

Playback/Record Session in Incorrect State

Used in messages Play File Modify, Record File Modify

17 05

Invalid File ID for Configuration

Used in messages Play File Start, Record File Start

17 07

No Resources Due to DSP Overload

Used in messages Resource Create, Play File Start (to channel or conference), Record File Start (to channel or conference), Conference Create, DSP Service Request, Collect Digit String, Recorded Announcement Connect, Connect Tone Pattern, Outpulse Digits

MSB 0x18 - Invalid B Channel State

The LSB indicates the current call state.

If the value is 0x1850 or above, it indicates the Layer 3 State. The Layer 3 state values depend on the signaling protocol. See the appropriate *.ppl file (CD ROM only) for Layer 3 state values, or contact Excel technical support.

 

If the value is lower than 0x1850, it indicates the Layer 4 State. The Layer 4 states are defined below. Some values are not backward-compatible with System Software versions earlier than 5.3.

18 00

Out of Service

18 01

Incoming Call

18 02

Wait For CSA in Incoming Call State

18 03

In Service Idle

18 04

Incoming Call, Wait for Host Connect

18 05

Outgoing Call, L3 Outseize Wait

18 06

Wait For CSA in Incoming Call Wait for Host State

18 07

Answered/Connected

18 08

L4 Clear ACK Wait, L3 Disconnect Received

18 09

L3 Clear Wait

18 0A

Busied out

18 0B

Outgoing Call Cut-thru

18 0C

Wait for CSA in Incoming Alerted State

18 0D

Wait for CSA in Incoming in Answered State

18 0E

Incoming Call Alerted

18 0F

L3 Clear Wait

18 10

Wait for CSA in Outgoing Cut-thru

18 11

Wait for CSA in Outgoing Alerted State

18 12

L4 Clear ACK Wait, L3 Clear Received

18 13

Outgoing Call Alerted

18 14

L4 Clear ACK Wait, L5 Clear Received

18 15

L5 Release Wait

18 16

Incoming Call, L4 Clear ACK Wait (Park Processing)

18 17

Incoming Call Alerted, L4 Clear ACK Wait (Park Processing)

18 18

Answered, L4 Clear ACK Wait (Park Processing)

18 19

Outgoing Alerted, L4 Clear ACK Wait (Park Processing)

18 1A

Outgoing Cut-thru, L4 Clear ACK Wait (Park Processing)

18 1B

Wait for CSA for Internal Routing

MSB 0x1D - Invalid A Channel State

The LSB indicates the current call state.

If the value is 0x1D50 or above, it indicates the Layer 3 State. The Layer 3 state values depend on the signaling protocol. See the appropriate *.ppl file (CD ROM only) for Layer 3 state values, or contact Excel technical support.

 

If the value is lower than 0x1D50, it indicates the Layer 4 State. The Layer 4 states are defined below. Some values are not backward-compatible with System Software versions earlier than 5.3.

1D 00

Out of Service

1D 01

Incoming Call

1D 02

Wait For CSA in Incoming Call State

1D 03

In Service Idle

1D 04

Incoming Call, Wait for Host Connect

1D 05

Outgoing Call, Layer 3 Outseize Wait

For PPL Event Request message (0x0044): Outseize Acknowledgment Network Wait

1D 06

Wait For CSA in Incoming Call Wait for Host State

1D 07

Answered/ Connected

1D 08

L4 Clear ACK Wait, Layer 3 Disconnect Received

For PPL Event Request message (0x0044): Layer 4 Release Wait

1D 09

Layer 3 Clear Wait

For PPL Event Request message (0x0044): Network Release Wait

1D 0A

Busied out

1D 0B

Outgoing Call Cut-thru

For PPL Event Request message (0x0044): Externally Outseized

1D 0C

Wait for CSA in Incoming Alerted State

For PPL Event Request message (0x0044): Hold Acknowledge Wait

1D 0D

Wait for CSA in Incoming in Answered State

 

For PPL Event Request message (0x0044): Layer 3 Answer Wait

1D 0E

Incoming Call Alerted

For PPL Event Request message (0x0044): Layer 4 Answer Wait

1D 0F

L3 Clear Wait

1D 10

Wait for CSA in Outgoing Cut-thru

For PPL Event Request message (0x0044): Layer 4 Recall Wait

1D 11

Wait for CSA in Outgoing Alerted State

For PPL Event Request message (0x0044): Purge Response Wait

1D 12

L4 Clear ACK Wait, L3 Clear Received

For PPL Event Request message (0x0044): Purge Wait

1D 13

Outgoing Call Alerted

For PPL Event Request message (0x0044): Park

1D 14

L4 Clear ACK Wait, L5 Clear Received

1D 15

L5 Release Wait

1D 16

Incoming Call, L4 Clear ACK Wait (Park Processing)

1D 17

Incoming Call Alerted, L4 Clear ACK Wait (Park Processing)

1D 18

Answered, L4 Clear ACK Wait (Park Processing)

1D 19

Outgoing Alerted, L4 Clear ACK Wait (Park Processing)

1D 1A

Outgoing Cut-thru, L4 Clear ACK Wait (Park Processing)

1D 1B

Wait for CSA for Internal Routing

48 01

Invalid Number of TLVs

The number of TLVs is out of range.

48 02

Invalid Module Number

The module number is invalid for the message sent.

48 03

Invalid IP Address

The IP address out of range or an invalid class.

48 04

Invalid Subnet Mask

The subnet mask is out of range or is invalid for the IP address.

48 05

Duplicate IP Address

The IP address is already assigned to another module number.

48 06

Invalid TLV tag

The TLV tag is out of range.

48 07

Invalid Data Type

The Data Type is out of range.

48 08

Invalid TLV combination

The combination of TLVs is invalid.

48 09

Module Not Present

 

48 11

Socket Incorporate Operation Error

 

48 12

Invalid Parameter Length

 

48 0A

Invalid IMSG

 

48 0B

Motherboard IP Address Not Configured

 

48 0C

Invalid Ethernet Port

 

48 0D

Invalid TLV Value

 

48 0F

Socket bind to user error

 

4D 01

Software key format not valid.

 

The first two bytes of the Product License field are not defined key types, or the product license contains invalid data.

4D 02

Data decrypted not valid.

 

A serial number decrypted from a product license cannot be matched against an existing serial number on a Excel platform.

4D 03

Product License - Insufficient Licensed Resources

4D 3D

Product License - Invalid ICB Data

4D 74

Invalid Card Type.

The line card that license was generated for does not support licensing

4D AA

Insufficient Hardware.

Not enough room for the number of licensed spans on the chassis

50 01

Response Timeout

50 02

Null Buffer

50 03

Queue Full

50 04

Feature Disabled

50 05

No ICBs

50 06

Invalid ICB Type (Message Not Processed)

50 07

Invalid ICB Type (Message Partially Processed)

50 08

Invalid ICB Subtype (Message Not Processed)

50 09

Invalid ICB Subtype (Message Partially Processed)

50 0A

Invalid Message (Message Not Processed)

50 0B

Invalid Message (Message Partially Processed)

50 0C

Unauthorized Command

50 0D

Incorrect ICB Data Length

50 0E

Host Not Connected

50 0F

Incorrect Host ID

50 10

Reserved

50 11

Maximum Number of Queries Exceeded

50 12

Not used

50 13

Not used

50 14

Multi Host Download In Progress

50 15

Multi Host Being Enabled, Wait 32 Sec

In the SS7 CLLI Query message (0x00EB):

The message could not be processed for either of the following reasons:

- Stack ID and CIC Group mismatch

- Internal error

50 16

Odd ICB Data Count (Extended API)

50 17

Non-Unique Host ID

In the SS7 CLLI Query message (0x00EB):

Invalid configuration data format, if the data format specified is not 0x01 (TLV format)

50 18

Invalid ICB Subtype

50 19

Host ID Assigned to Different Host

50 1A

Invalid ICB Data Entry

50 47

Invalid Ring Loop Timing.

 

Trying to set a node to be master-configurable, but the ring timing has already been derived, or trying to set ring timing on a master node or master- configurable node, or trying to set secondary timing on the EXNET-ONE card.

50 AA

Insufficient Hardware.

 

This response status is returned when trying to initiate the Enhanced Fault Tolerance Ring Mode, but the EXNET-ONE and I/O are installed. (These EXNET cards cannot be used in the Enhanced Fault Tolerance Ring Mode).

50 C0

Action Denied.

 

A value of Action Denied (0xC0) is returned if the user is trying to set an EXNET-ONE card.

50 75

Invalid TLV Tag.

The TLV specified is not one of the 4 types allowed (Trunk Number, Local CLLI, Remote CLLI, Trunk Type)

50 CD

Invalid TLV Tag Length

50 E0

SS7 Signaling Stack Not Configured

50 F9

Invalid TLV Count. The TLV Count should be 0x04.

51 01

End of Route Table

51 02

Retry Limit Exceeded

51 03

Termination Error

51 04

Purge

51 05

No Destination Found

51 06

Recursion

51 07

ACK Wait Timer Expired

51 08

No Common Resource Group Found

51 0A

Termination Validation Error

51 0B

Channel unavailable due to initialization or OOS

51 0C

End of Entry Data

51 0D

Invalid Routing Method

51 0E

Invalid Resource Group Table

51 0F

Invalid Route Table

51 10

Reserved

51 11

Invalid Resource Group

51 12

Invalid Criteria

51 13

Invalid Entry Data

No available routes

51 14

System Error

51 15

Illegal Instruction

51 1E

V5 ID Invalid

51 1F

V5 User Port Invalid

51 8F

Gatekeeper routed but no gatekeeper address

 

51 90

H245 end session received

 

51 91

RAS DRQ

 

51 92

CALL PROCEEDING has protocol error

 

51 93

H225 timer expired

 

51 94

REL COMPLETE received

 

51 95

Incoming H225 message has Q931 protocol error

51 96

No Remote Alias Address or SRC IP/Port not Available

51 97

H.323 Protocol Error (H.225, H.245, or RAS)

51 98

H.225, H.245 Socket Open Fail

51 99

Gatekeeper not Configured

51 9A

LRQ Failed

51 9B

ARQ Failed

51 9C

No Associated Timeslot

51 9D

DSP Resource Wait Timeout

51 9E

Invalid DSP Resource Request

Resource already attached.

51 20

V5 ID Invalid

51 21

V5 User Port Invalid

51 22

V5 User Port Blocked

51 23

V5 Timer Expiry

51 24

Unexpected Clearing Received

51 25

Invalid V5 Formatted IEs

51 26

Invalid Number of V5 Formatted IEs

52 01

Signaling Route Test (SRT) failed.

52 02

Signaling Route Test Acknowledgment (SRTA) has an improper pattern.

52 03

The SRTA was received on the wrong SLC. (This error code not supported for DDI).

52 04

Link congested

52 05

Link out of service

52 06

Link not equipped

52 07

Request was terminated by the Host

52 08

SRT is already running

52 09

System error

52 0A

SRTC timed out

52 0B

Received valid SRTA in wrong Link ID (This error code not supported for DDI)

52 0C

Route not configured for this DPC

52 81

Invalid module type for DPC/Stack/CIC combination. (Also used in the PPL Timer Configure message: 0x00CF)

52 82

Message received for unassigned CIC.

52 83

Only Extended API is supported for VCIC.

If the MSB is 0x54, Error Detected in SCCP/TCAP, the LSB indicates the error as follows:

54 00

Error Unknown

54 01

Incorrect ICB

The maximum number of ICBs for the TCAP primitive set is 16.

54 02

Incorrect ICB Length or Parameter

54 03

Incorrect or Missing Mandatory TCAP Parameters

54 04

Incorrect or Missing Mandatory SCCP Parameter

54 05

Invalid Primitive (Primitive Not Supported)

54 06

Instance does not Exist

54 07

Primitive Not Expected as this Time

54 08

Mandatory Component Missing

54 09

TCAP simultaneous active dialogue/transaction/operations reached the maximum limit.

SS7 system busy condition (for CPU, memory or MCB).

54 0A

SSN is not Configured or not Active

54 0B

Maximum Length of TCAP Components for a Message Exceeded

55 00

PPL Event Request: Error Unknown

SCCPTCAP Configure: No More Status Info, or Status Unknown

55 01

PPL Event Request: Invalid ICB or a Mandatory ICB is missing

SCCPTCAP Configure: Invalid Config Type

55 02

PPL Event Request: Incorrect ICB Length or Parameter

SCCPTCAP Configure: Subsystem Configured

55 03

PPL Event Request: Incorrect or Missing Mandatory TCAP Parameter

SCCPTCAP Configure: Subsystem Not Configured

55 04

PPL Event Request: Incorrect or Missing Mandatory SCCP Parameter

SCCPTCAP Configure: Subsystem Allowed

55 05

PPL Event Request: Invalid Primitive (Primitive Not Supported)

SCCPTCAP Configure: Subsystem Not Allowed

55 06

PPL Event Request: Instance does not Exist

SCCPTCAP Configure: Invalid Option

55 07

PPL Event Request: Primitive Not Expected at this Time

SCCPTCAP Configure: Exceeds minimum number of hosts for a Subsystem

55 08

PPL Event Request: Mandatory Component Missing

SCCPTCAP Configure: Invalid Parameter

55 09

PPL Event Request: Resource Limitation

SCCPTCAP Configure: Invalid Parameter Length

55 0A

PPL Event Request: SSN is not Configured or not Active

SCCPTCAP Configure: Parameter Configured

55 0B

PPL Event Request: Maximum Length of TCAP Components for a Message Exceeded

SCCPTCAP Configure: Parameter Not Configured

55 0C

Invalid SCCP Upper Layer

55 0D

Maximum Active Subsystems Exceeded

55 0E

DPC Not Configured

List