The poll interval, which is in 10 milliseconds, should be configured with values greater than 5. If configured with anything less than 5, the IP Signaling Series 3 card will automatically set the poll interval to 5.
Important! This poll is the IP Signaling Series 3 card to Matrix poll not the IP Signaling Series 3 card to Host poll.
Used in:
IP Signaling Series 3 Card Configure message (0x0100)
IP Signaling Series 3 Card Query message (0x0101)
Byte |
Description |
0, 1 |
Tag 0x000A |
2, 3 |
Length 0x0004 |
4, 5 |
Value[0] Number of Seconds Between Polls 0x00 - 0xFF In 10 millisecond units |
6, 7 |
Value[1] Number of Missed Polls Before Link is Declared |