This timer is used when the link between the IP Signaling Series 3 Card and the Matrix Controller goes down. If there is a secondary Matrix Controller present in the node, the IP Signaling Series 3 card triggers this timer and does not release any active calls (calls in the answered state). The IP Signaling Series 3 card waits until the timer expires to re-establish the connection with the secondary matrix.
If the connection is re-established, all the active calls stay connected; however, no new calls (incoming or outgoing) can be made when the link between the Matrix Controller and IP Signaling Series 3 card is temporarily down.
If the link is not re-established or if there is no secondary Matrix Controller in the node, all of the active calls are released on the H.323 (IP) end.
Used in:
IP Signaling Series 3 Card Configure message
IP Signaling Series 3 Card Query message
Byte |
Description |
0, 1 |
Tag Link Down Timer |
2, 3 |
Length 0x02 |
4, 5 |
Value[0, 1] Timer in 10 ms intervals (MSB, LSB). 0x2EE0 (Default is 12000 seconds - 2 minutes) |