0x0118 Companding Conversion Mode

Use this TLV to specify whether PCM encoding format conversion should be bypassed or not. The default is 0 in which case PCM encoding format is not bypassed. A value of 1 bypasses the conversion process and forces the B side of the call leg to use the A side’s companding format.

Used in:
0x1E and 0x001E Generic PPL ICBs in:
Route Control message
Connect with Data message

Byte

Description

0, 1

Tag 0x0118

2, 3

Length 0x0001

4

Value[0] 0x00 Companding Conversion

enabled (default)

0x01 Companding Conversion

disabled