AF Number

91

Name

Set Unequipped Bit and clear all other status for CIC

Description

Resets the CIC state database by clearing all status bits and setting the ‘unequipped’ bit.

Arg1

<Not Used>

Arg2

<Not Used>

AF Number

92

Name

Send Message to UCIC

Description

Delivers an incoming message to UCIC.

Arg1

<Not Used>

Arg2

<Not Used>

AF Number

93

Name

Update HW Blocking Circuit Status

Description

Updates the ‘Hardware Blocking’ status bits (Hardware Local Blocked, Hardware Remote Blocked) in the CIC state database based on receiving an update message from an ISUP state machine.

Arg1

<Not Used>

Arg2

<Not Used>

AF Number

94

Name

Update Maintenance SM Circuit Status

Description

Updates the maintenance-related status bits (Maintenance Unblock Wait, Hardware Unblock Wait, CRCR Recheck Active) in the CIC state database based on receiving an update message from an ISUP state machine.

Arg1

<Not Used>

Arg2

<Not Used>

AF Number

95

Name

Send MSG to CRCR

Description

Delivers an incoming MSU to CRCR.

Arg1

<Not Used>

Arg2

<Not Used>

AF Number

96

Name

Test Circuit Status for CRCR Recheck

Description

Tests if CRCR Recheck is active for a CIC.

Arg1

<Not Used>

Arg2

<Not Used>

Test Result

PPL Internal Event

No (Inactive)

0

Yes (Active)

1

AF Number

97

Name

Test Message Parameter with Bit Mask

Description

Tests a bit field within the parameter indicated by Arg1.

The most significant byte of Arg2 is used as a byte offset into the parameter. The least significant byte of Arg2 is used as a bit mask which is masked with the byte in the parameter specified in the MSB of Arg2. The result is then right-shifted until the right-most bit in the mask is in the least significant bit

Arg1

<Not Used>

Arg2

<Not Used>

 

Test Result

PPL Internal Event

Value

0 + value of bit field

AF Number

98

Name

Send Message to MGBR

Description

Delivers an incoming message to MGBR.

Arg1

<Not Used>

Arg2

<Not Used>

AF Number

99

Name

Send Message to MGBS

Description

Delivers an incoming message to MGBS.

Arg1

<Not Used>

Arg2

<Not Used>

AF Number

100

Name

Send Message to HGBR

Description

Delivers an incoming message to HGBR.

Arg1

<Not Used>

Arg2

<Not Used>

AF Number

101

Name

Send Message to HGBS

Description

Delivers an incoming message to HGBS.

Arg1

<Not Used>

Arg2

<Not Used>

AF Number

102

Name

Test Circuit Status for Transient

Description

Tests the ‘transient’ status bit in the CIC state database.

Arg1

<Not Used>

Arg2

<Not Used>

 

Test Result

PPL Internal Event

Bit not set

0

Bit set

1

AF Number

103

Name

CPC Circuit Status and remove unequipped status

Description

Updates the ‘CPC’ status bits and clears the ‘unequipped’ status bit in the CIC state database.

Arg1

<Not Used>

Arg2

<Not Used>

AF Number

104

Name

Clear status bits for unequipped circuits. Test if number of status bits is range

Description

Tests if the range field of the Range and Status parameter of an incoming message is in the range defined by Arg1 and Arg2.

The status bits for all unequipped circuits from the status field in the Range and Status parameter are cleared.

Arg1

<Value 1> Beginning of range.

Arg2

<Value 2> End of range.

Test Result

PPL Internal Event

In range

1

Not in range

0

AF Number

105

Name

Send L5 PPL Event Indication for stack

Description

Sends a PPL Event Indication to the host with entity of stack and event given by Arg1.

Arg1

<Event ID>

Arg2

<Not Used>

AF Number

106

Name

Place DPC in UPU queue

Description

Places the DPC given in the MTP indication in the UPU queue.

Arg1

<Not Used>

Arg2

<Not Used>

AF Number

107

Name

Check for DPC in UPU Queue and remove

Description

Tests the User Part Unavailable (UPU) queue for the DPC given in the MTP indication and, if there, removes it.

Arg1

<Not Used>

Arg2

<Not Used>

Test Result

PPL Internal Event

DPC in queue

1

No DPC in queue

0

AF Number

108

Name

Send L3P User Part Accessible

Description

Sends L3P an indication that a remote ISUP has become accessible.

Arg1

<Not Used>

Arg2

<Not Used>

AF Number

109

Name

Clear Unequipped Bit for CIC

Description

Clears the ‘unequipped’ status bit in the CIC state database.

Arg1

<Not Used>

Arg2

<Not Used>

AF Number

110

Name

Update CPC Circuit Status

Description

Updates the ‘CPC’ status bits in the CIC state database.

Arg1

<Event ID>

Arg2

<Not Used>

AF Number

129

Name

Sprc_af_129

Description

Find MCP parameter in the unrecognized message.

Arg1

<Event ID>

Arg2

<Not Used>

Test Result

PPL Internal Event

If parameter found

1

If parameter not found

0

AF Number

130

Name

Sprc_af_130

Description

Send unrecognized message PPL event indication containing unrecognized message to the host, with channel AIB.

Arg1

<Event Indication ID> 0-255

Arg2

<Not Used>

AF Number

131

Name

Sprc_af_130

Description

Send a release with cause value 97 to the network and send and indication to CPC.

Arg1

<Not Used>

Arg2

<Not Used>

AF Number

133

Type

Test

Name

SPRC test if Host controlled continuity enabled

Description

Looks into the common CPC area and checks if the Host Controlled Continuity is enabled.

Arg1

None

Arg2

None

Test AF Results

PPLevIntEVENT_0,PPLevIntEVENT_1