L3P CIC (0x000F)

 

This section documents the atomic functions associated with L3P CIC.

Atomic Functions

The following AFs are specific to the L3P CIC Call Control PPL component.

AF Number

51

Name

Send L4 Channel Status In Service

Description

Sends L4 a channel in service indication.

Arg1

<Not Used>

Arg2

<Not Used>

AF Number

52

Name

Send ISUP Circuit Reset

Description

Sends ISUP a CIC reset request using no parameters.

Arg1

<Not Used>

Arg2

<Not Used>

AF Number

53

Name

Fault

Description

Generates an SS7 card fault using fault code in Arg1.

Arg1

<Fault Code>

Arg2

<Not Used>

AF Number

54

Name

PPL Restore Channel’s Assigned Protocol

Description

Function to switch from the OOS to the INS protocol.

Arg1

<Fault Code>

Arg2

<Not Used>

AF Number

55

Name

PPL Send L5 PPL Event Indication using L4/L5 Outgoing Buffer

Description

Sends a PPL Event Indication to the host using the event ID in Arg1 and sending up any ISUP parameters stored in the L4/L5 outgoing buffer.

Arg1

<Event ID>

Arg2

<Not Used>

AF Number

56

Name

Send L4 a Cut Through

Description

Sends L4 a cut through indication.

Arg1

<Not Used>

Arg2

<Not Used>

AF Number

57

Name

Send L5 PPL Event

Description

Sends a PPL event indication to the host using the Event ID in Arg1 and sending up ICB with the data in Arg2.

Arg1

<Event ID>

Arg2

<Event Data>

AF Number

58

Name

Send ISUP OOS Maintenance Loopback Ack

Description

Notifies ISUP that the requested PCM loopback has been established.

Arg1

<Not Used>

Arg2

<Not Used>

AF Number

59

Name

Copy Default ISUP Parameters into L5 Incoming Buffer

Description

Loads the PPL Config Byte prestored parameters at offset in Arg1 into the L5 incoming buffer.

Arg1

<Config Byte Offset of Defaults>

Arg2

<Not Used>

AF Number

61

Name

Test for Existence of BCD Encoded Digits in Message

Description

Tests an Outseize Control message for the existence of BCD digits.

Arg1

<Not Used>

Arg2

<Not Used>

Test Result

PPL Internal Event

Digits not present

0

Digits present

1

AF Number

62

Name

Send L4 a Q.931 Connect Message

Description

Sends L4 a Connect Indication.

Arg1

<Not Used>

Arg2

<Not Used>

AF Number

63

Name

Send L4 a Q.931 Disconnect

Description

Sends L4 a disconnect Indication.

Arg1

<Not Used>

Arg2

<Not Used>

AF Number

64

Name

Send L4 a Q.931 Clear using L4/L5 Outgoing Buffer

Description

Sends L4 a Clear indication including any parameters present in the L4/L5 outgoing buffer.

Arg1

<Not Used>

Arg2

<Not Used>

AF Number

65

Name

Send L4 OOS Maintenance Loopback

Description

Send L4 an OOS indication which also requests that a PCM loopback be connected to the channel.

Arg1

<Not Used>

Arg2

<Not Used>

AF Number

66

Name

Send L4 an Out of Service Message

Description

Sends an Out of Service message to L3/L4 with the reason indicated by Arg1.

Arg1

<Reason>

Arg2

<Not Used>

AF Number

67

Name

Test L5 Incoming Buffer for parameters and assemble with defaults

Description

Search the L4/L5 incoming buffer for an ICB relating to the message configuration specified in Arg1. If found, the ICB is concatenated with prestored parameters in the Config Bytes at the index specified by Arg2 and the resulting ICB is placed into the L4 /L5 incoming buffer.

Arg1

<ISUP Message Config Index>

Arg2

<Config Byte with Default>

Test Result

PPL Internal Event

No ICB Found

0

ICB Found

1

AF Number

68

Name

Copy Default ISUP Parameters and use BCD-Encoded digits into L5 Incoming Buffer

Description

Searches for a Stage N Address Data ICB w/ BCD encoded digit strings in the L4/L5 incoming buffer. The digits are translated into SS7 Called and Calling Party Number parameters using the parameter IDs specified in the MSB (Called Party) and LSB (Calling Party) of Arg2.

The parameters are concatenated with prestored parameters in the config bytes at the index specified in Arg1. The resulting ICB is stored in the L4/L5 incoming buffer.

Arg1

<Config Byte Offset Of Defaults> 1-200

Arg2

<Called Number Party ID/Calling Number Party ID>

AF Number

69

Name

Send L4 a Q.931 SETUP using L4/L5 Outgoing Buffer

Description

Sends L4 a call SETUP indication including any SS7 parameters present in the L4/L5 outgoing buffer.

Arg1

<Not Used>

Arg2

<Not Used>

AF Number

71

Name

Transfer L5 Formatted Raw SS7 Parameters from L4/L5 Incoming to ISUP Outgoing Buffer

Description

Searches the L4/L5 incoming buffer for the ICB corresponding to the message configuration specified by Arg1. Once found, the ICB is transferred to the ISUP outgoing buffer.

Arg1

<ISUP Message Config Index>

Arg2

<Not Used>

AF Number

72

Name

Send L4 a Q.931 Alerting

Description

Sends L4 an alerting indication including any parameters present in the L4/L5 outgoing buffer.

Arg1

<Not Used>

Arg2

<Not Used>

AF Number

73

Name

Test for Existence of SS7 Parameters in Message

Description

Test any message for the presence of SS7 ICB buffers.

Arg1

<Not Used>

Arg2

<Not Used>

Test Result

PPL Internal Event

No parameters present

0

Parameters present

1

AF Number

74

Name

Purge Channel

Description

Initiates a channel purge with purge reason specified in Arg1.

Arg1

<Purge Code>

Arg2

<Not Used>