CPA Classes

 

The parameters associated with a CPA class are defined in Table 7-16. To modify a class or to add a new class, use the CPA Class Configure message. The Excel platform supports up to 15 classes. A class can contain up to 15 pattern members, and 30 patterns are allowed for each Excel platform. Class elements are given in Table 7-15.

Table 7-15 CPA Classes

Class

Standard N.A.
0x00

Dial Tone
0x01

CPC Det.
0x02

Energy Det.
0x03

Mode

0x01
(Adv. Ans. Det.)

 

 

Energy Detection

Tone Burst Answer Threshold

4/250 ms

 

 

4/500 ms

Start Delay

0x00

0x00

0x00

0x00

Continuous Silence Timeout (ms)

25,000

25,000

0xFFFF

25,000

Confirmation (ms)

13,000

25,000

0xFFFF

13,000

Confirmation/No Report (ms)

22,000

15,000

0xFFFF

22,000

Minimum Frequency Glitch Time (ms)

40

20

20

20

Minimum Silence Glitch Time (ms)

60

20

20

60

Maximum On Timer (ms)

2,800

25,000

0xFFFF

2,800

Maximum Off Timer (ms)

5,000

25,000

0xFFFF

5,000

Mode Specific Value 1

0x0000

0x0000

0x0000

0x0005

Mode Specific Value 2

0x0000

0x0000

0x0000

0x0002

Patterns in Class

0x01 Ringback
0x02 Double Ringback
0x03 Busy
0x04 Reorder
0x05 PBX Intercept
0x06 SIT Intercept
0x07 Vacant Code
0x08 Reorder-LEC
0x09 No Circuit LEC
0x0A Reorder Carrier
0x0B No Circuit Carrier
0x0C PBX Dial Tone
0x0D Standard Dial Tone

0x0C PBX Dial Tone

0x0D Standard Dial Tone

0x0E CPC Detection

0x01 Ringback

0x02 Double Ringback

0x03 Busy

0x04 Reorder