L3 BT IUP CPC Configuration Bytes

Byte

Definition

Value

0x01

Network Configuration

Bit Number Description

0=Controlled Network (default)

1=Controlling Network

0x02

Confusion Message Qualifier value

Whenever CPC sends the Confusion message this byte will be used to setup the message qualifier byte.

0 (default)

0x03

Incoming Congestion Control.

0=Enabled (default)

1=Disabled

0x04

Release Procedures

0 = Both way Procedures

1 = Disabled

0x05

Unidirectional Customer Location

(i.e. Outgoing Network Location)

Used for Idle Release Procedures

0 = Other End

1 = This End

0x06

Bearer Release Outgoing Initiated, Subsequent to sending the third release processing procedure

0 =Assume Circuit is Blocked

1 = Repeatedly send a Release upon expiry of TO-12

2 = Assume circuit is Idle, ready to accept another call.