L3P System Management Component PPL Timers (0x0090)
When specifying new timer values, remember that all PPL Timers are specified in 10 ms increments. For example, a PPL timer for 4 seconds is specified as 4000 (decimal, 400 x 10 ms = 4 seconds), which is the hexadecimal value of (0x190).
Timer ID |
Description |
Value (default) |
---|---|---|
0x01 |
Waiting for MDU Control (restart acknowledge) from all PSTN protocol State Machines |
100 seconds |
0x02 |
Waiting for MDU Control (restart complete) from Control Data Link |
120 seconds |
0x03 |
Waiting for MDL Establish Confirm or MDL Establish Indication from Control Data Link |
15 seconds |
0x04 |
Waiting for MDL Establish Confirm or MDL Establish Indication from Control Data Link |
60 seconds |
0x05 |
Waiting for MDL Establish Confirm or MDL Establish Indication from PSTN Data Link |
25 seconds |
0x06 |
Waiting for MDL Establish Confirm or MDL Establish Indication from Link Control Data Link |
15 seconds |
0x07 |
Waiting for MDL Establish Confirm or MDL Establish Indication from Link Control Data Link |
60 seconds |
0x08 |
Waiting for MDL Establish Confirm or MDL Establish Indication from BCC Data Link |
15 seconds |
0x09 |
Waiting for MDU Control (Unblock all relevant ports accepted) |
20 seconds |
0x0A |
Waiting for MDU Control (Unblock all relevant ports accepted) |
10 seconds |