Configuring Overload Management

Configuration

To configure the overload threshold values, the number of times that the threshold must be exceeded (M), and the size of the sample window (N), use the Generic Card Configure 0x0122 message (0x0122) with the Alarm Threshold TLV (0x05EF) and these Alarm types:

0x0A CPU Idle Time

0x0B VRA Process Time

0x0C VRA IO Queue Time

Query

To query the overload thresholds, use the Generic Card Query 0x0123 message (0x0123) with the 0x05FA Card Object TLV.

To query the overload statistics, use the Statistics Query 0x0121 message (0x0121) with a slot AIB and the 0x0616 DSP Series 2 Overload Statistics (0x0616).

TLVs for DSP Series 2 Overload Management

0x0616 DSP Series 2 Overload Statistics

0x0617 Alarm Threshold Query

0x0618 Alarm Threshold Enabled Report