ISUP SSC (0x0085)

 

This section documents the atomic functions associated with ISUP SSC.

Atomic Functions

AF Number

52

Name

Send ISUP message to CPC

Type

Normal

Description

Sends message with the event specified in arg1 to CPC

Arg1

Event

 

0 : 255

Arg2

<Not Used>

AF Number

53

Name

Test parameter with bitmask

Type

Test

Description

Test the parameter provided in arg1 with the bit-mask in the in arg2.

Arg1

Parameter ID

 

0 : 255

Arg2

Bitmask

 

0 : 255

Result

PPLevIntEVENT_1 – If Bit mask qualifies

PPLevIntEVENT_0 – If it does not

AF Number

54

Name

Store Message in buffer

Type

Normal

Description

Store the message in the MSG buffer.

Arg1

<Not Used>

Arg2

<Not Used>

AF Number

55

Name

Assemble message in buffer

Type

Normal

Description

Assemble the message in MSG and SGM buffer into the MSG buffer.

Arg1

<Not Used>

Arg2

<Not Used>

AF Number

56

Name

Send SGM message to L3P

Type

Normal

Description

Send the incoming Segmentation Message to L3P.

Arg1

Event ID

 

0 : 255

Arg2

<Not Used>

AF Number

57

Name

Send ISUP message to L3P

Type

Normal

Description

Send the incoming ISUP message to L3P.

Arg1

Event ID

 

0:255

Arg2

<Not Used>

AF Number

58

Name

Send Pass-through message to L5

Type

Normal

Description

Forward Pass through message to L5.

Arg1

ISUP message config index

 

0 :255

Arg2

<Not Used>

AF Number

59

Name

Forward Incoming Message to L3P

Type

Normal

Description

Forwards Call control messages to L3P.

Arg1

Event

 

0 : 255

Arg2

<Not Used>

AF Number

60

Name

Forward Message to CPC

Type

Normal

Description

This messages forwards the message to CPC without any changes to it.

Arg1

Event

 

0: 255

Arg2

<Not Used>

AF Number

61

Name

Send the Segmented Message to CPC

Type

Normal

Description

The AF sends the constructed SGM message to CPC.

Arg1

Event ID

 

0:255

Arg2

<Not Used>

AF Number

62

Name

Store message in SGM buffer

Type

Normal

Description

Store incoming SGM message in SGM buffer.

Arg1

<Not Used>

Arg2

<Not Used>

AF Number

63

Name

Test COT check flag in CPC

Type

Normal

Description

Test COT wait before RFS flag in CPC.

Arg1

<Not Used>

Arg2

<Not Used>