Indicates the redundancy state of the board to the local application. This event is received immediately after binding (if the board state has already been determined), or any time the redundancy state changes between PRIMARY and BACKUP states. The SCCPRUNSTATEIND event does not return any data other than the content of the SccpRcvInfoBlk. For more information, refer to Handling redundancy events.
SccpRcvInfoBlk
Field |
Description |
board |
Not used. The CTAHD handle that delivered the event identifies the board that originated the event. |
indType |
SCCPRUNSTATEIND |
evntType |
New redundancy state of the board: SPRS_STANDALONE SPRS_PRIMARY SPRS_BACKUP |
suId |
Application service user ID that identifies with which SCCP user SAP this message is associated. |
connId |
Not used. |
opc |
Point code of the concerned signaling point whose state changed. |