Specifies a source to drive the NETREF timing signal on the CT bus.
For more information about setting up CT bus clocking and about the rules and restrictions that apply to setting up clocking with CG 6565C boards, refer to Configuring board clocking.
Clocking.HBus.NetRefSource = source
Read/Write
String
OSC
OSC | NETWORK | STANDALONE
Clocking.HBus.NetRefSource = STANDALONE
Valid entries include the following values:
Value |
Description |
---|---|
OSC |
Specifies that the oscillator uses the board's local clock (for diagnostics only). |
NETWORK |
Specifies that the timing signal is derived from a device source (digital trunk). When using this keyword, you must also specify the trunk number with Clocking.HBus.NetRefSourceNetwork. |
STANDALONE |
Specifies that the NETREF clock is not driven. |