Specifies the type of cable connecting a CG 6565C board to the network.
NetworkInterface.T1E1[x].Impedance = cable_type
x = 0-(n-1) (0-based trunk number or range of trunk numbers where n equals the number of trunks on the board.)
Read/Write
String
G703_120_OHM
DSX1 | G703_120_OHM
NetworkInterface.T1E1[0..7].Impedance = G703_120_OHM
Trunk impedance on the CG 6565C is controlled through a board configuration file. Since trunks are configured in pairs, the configuration setting must be identical for both trunks in a given pair. Trunks are paired as follows:
0 and 1
2 and 3
4 and 6
6 and 7
8 and 9
10 and 11
12 and 13
14 and 15
Valid settings are:
Setting |
Description |
---|---|
DSX1 (T1 only) |
For DSX1 cables (up to 655 feet - short haul). |
G703_120_OHM (E1 only) |
For G.703-standard 120 ohm cables. |
To connect a CG 6565C board to a 75-ohm E1 trunk, configure the board as E1 120 ohm and connect a shielded 50-pin Telco cable to a punchdown block or signal entry panel (SEP). Then connect the punchdown block or SEP to a 75 ohm BNC SEP or equivalent to convert the impedance from 120 ohm to 75 ohm.
For more information, refer to Configuring the T1 or E1 interface.