L3P Call Control PPL Timers (0x0005)

When specifying new timer values, remember that all PPL Timers are specified in 10 ms increments. For example, a PPL timer for 4 seconds is specified as 4000 (decimal, 400 x 10 ms = 4 seconds), which is the hexadecimal value of (0x190).

Timer ID

Description

Value (default)

0x01

Outseize Response Wait

60 seconds

(6000 10ms units)

0x02

Register Request Wait

8 seconds

For Euro-ISDN only

0x02

INFO message wait for Overlap Receive

20 seconds

0x03

INFO message wait for Overlap Send

20 seconds

0x04

Register Request Wait

8 seconds