ISUP CVR Configuration Bytes (ANSI)
For the CLLI and CIN parameter formats in the table below, refer to ANSI T1-113.
Byte |
Description |
Value |
---|---|---|
0x01 |
CLII |
0x00=Not Configured 0x01=Configured (default) |
0x02 |
CIN |
0x00=Not configured 0x01=Configured (default) |
0x03 |
CGC Indicator |
0x00 (default) Bits 1, 0=Circuit Group Carrier Indicator 00=Unknown 01=Analog 10=Digital 11=Digital and Analog.
Bits 3, 2=Double Seizing Indicator 00=Always 00; configuration taken from CPC data. DO NOT CHANGE
Bits 5, 4=Alarm Carrier Indicator 00=Unknown 01=Software Carrier Handling 10=Hardware Carrier Handling 11=Spare
Bits 7, 6- Continuity Check Requirement Indicator 00=Unknown; 01=None; 10=Statistical; 11=Per Call |
0x04 |
Message ID |
0xEB (CVR) |
0x05 |
Number of Mandatory Parameters |
2 (default) |
0x06 |
CVR Indicator Parameter Code |
0xE6 |
0x07 |
CVR Indicator Parameter Length |
0x01 |
0x08 |
CGC Parameter Code |
0xE5 |
0x09 |
CGC Parameter Length |
0x01 |
0x55 |
CVT Indication to host |
0x00=Disable (default) 0x01=Enable |