This section contains default settings for ANSI PPL Timers, shown below by PPL component.
The MTP3 timers are accurate to 100 ms.
.
Timer ID |
Spec/Timer |
Default Value (10 ms) |
|
---|---|---|---|
RCAT (0x0032) |
0x01 |
T1.111/T16 |
175 |
RSRT (0x0033) |
0x01 |
T1.111/T10 |
4500 |
TCBC (0x0038) |
0x01 |
T1.111/T3 |
80 |
0x02 |
T1.111/T4 |
80 |
|
0x03 |
T1.111/T5 |
80 |
|
TCOC (0x0039) |
0x01 |
T1.111/T1 |
80 |
0x02 |
T1.111/T2 |
140 |
|
TCRC (0x003A) |
0x01 |
T1.111/T6 |
80 |
TPRC (0x003D) |
0x01 |
T1.111/T22 |
6000 |
0x02 |
T1.111/T23 |
1000 |
|
0x03 |
T1.111/T26 |
1200 |
|
TRCC (0x003E) |
0x01 |
T1.111/T15 |
250 |
TSRC (0x0040) |
0x01 |
T1.111/T25 |
3000 |
0x02 |
T1.111/T28 |
1000 |
|
0x03 |
T1.111/T29 |
6000 |
|
SLTC (0x0041) |
0x01 |
T1.111/T1 |
800 |