SCCP SCLC Configuration Bytes

Byte

Description

Value

0x01

SCCP Message Format

0x00- International (default for ITU)

0x01=National (default for ANSI)

0x02=China Spec (same as ITU except the point code is 24 bits

0x02

UDTS Message Priority (ANSI Only)

0x02

0x03

N-Unidata *

0x00 - N-Unidata as UDT (Default)
0x01 - N- Unidata as XUDT

0x16-0x19

Used to store the X value.

150 (default)

0x20-0x1D

Used to store the Y value.

200 (default)

* The SCCP user sends SCCP N_UNITDATA to request sending data to a remote SCCP mode. The SCCP then packs the information in N_UNITDATA into an SCCP message and sends the message. The format of the message could be UDT or XUDT.

The XUDT message can be used with GTT to validate the hop counter to detect possible traffic loops. The maximum hop counter is set to 15. We recommend that if you use GTT and if the network supports XUDT, then you should set this SCLC configuration byte 3 to 0x01 to use XUDT message.

This configuration byte only applies to the messages without segmentation. If segmentation is needed, the SCCP will automatically pack and send the XUDT with the segmentation optional parameter.