L3P Control Protocol PPL Timers (0x008F)

When specifying new timer values, remember that all PPL Timers are specified in 10 ms increments. For example, a PPL timer for 4 seconds is specified as 4000 (decimal, 400 x 10 ms = 4 seconds), which is the hexadecimal value of (0x190).

Timer ID

Description

Value (default)

0x01

Waiting for Port Control
Acknowledge

1 seconds

0x02

Waiting for Common Control Acknowledge

1 seconds

0x03

Waiting for Datalink Connection Establish

4 seconds