0x0A Activate Ethernet Port (DSP Series 2 Card)

Use this TLV to assign the active Ethernet port for a DSP Series 2 card. If you enable Ethernet Link Redundancy (TLV 0x09), an available standby Ethernet Port is automatically activated upon failure of the active port. This TLV activates the Ethernet Interfaces on the Multi-Function Media I/O card as follows:

Upper port (NET1)

Middle port (NET2)

Lower port (NET3)

Used in:
IP Address Configure message
IP Address Query message

Byte

Description

0

Tag 0x0A Activate Ethernet Port

1

Length 0x04

2-5

Value[0] 0x00000001 Upper Port Active (NET1)
0x00000002 Middle Port Active (NET2)

0x00000003 Lower Port Active (NET3)

The two TLVs above (0x09 and 0x0A) are returned in the response to a successful IP Address Query message. If an 0x00FF is returned as the value of the Active Ethernet Port TLV (0x0A) in the response to a IP Address Query message, it indicates that Ethernet Link Redundancy is disabled.