You are here: CSP Developer’s Guide: Line Cards > 2 T1 Information > Default Instruction Lists
Default Inseize Instruction List
The default inseize instruction lists for T1 spans are shown in the table below.
Channel |
Instruction List |
---|---|
T1 |
1. Report Incoming Call |
Default Outseize Instruction Lists
The default outseize instruction lists for T1 spans are shown in the table below.
Channel |
Instruction List |
---|---|
T1 |
1. Wait For Host Control Message |
You must send a separate message for each instruction you add to the list. For example, to configure the following inseize instruction list on all of the channels on Span 0, send the following sequence of Inseize Instruction List Configure messages, with the specifications noted:
1. Generate Wink 1
2. Receive Stage 1 Digits
3. Report Incoming Call with Address Data
4. Wait for Host Control
Send the following Inseize Instruction List Configure messages:
Message 1:
Instruction Number: 0x01
Instruction Type: 0x02 (Generate Call Processing Event)
Instruction Data Byte 1: 0x03 (Wink 1)
Message 2:
Instruction Number: 0x02
Instruction Type: 0x03 (Receive Stage N Address Data)
Instruction Data Byte 1: 0x01 (Stage 1)
Message 3:
Instruction Number: 0x03
Instruction Type: 0x06 (Report Incoming Call With
Address Data)
Message 4:
Instruction Number: 0x04
Instruction Type: 0x04 (Wait For Host Control)