PBX BRAND |
PBX MODELS |
DIALOGIC MEDIA GATEWAYS |
PROTOCOLS |
LEVEL |
Alcatel |
Omni PCX 4400 |
DMG1008LS / DMG1004LS |
Analog - serial |
Lab Tested |
Alcatel |
Omni PCX 4400 |
DMG2000 Series (all models) |
T1-QSIG, E1-QSIG |
Lab Tested |
Alcatel |
Omni PCX 4400, 4410, 4199 |
DMG3000 (all models) |
BRI-QSIG |
Field Tested |
Alcatel |
Omni PCX 4400, 4410, 4200 |
DMG4000 (all models) |
T1-QSIG, E1-QSIG |
Field Tested |
Avaya |
Definity G3 |
DMG2000 Series (all models) |
T1-CAS |
Lab Tested |
Avaya |
Definity G3 |
DMG1008DNI |
Digital Set Emulation |
Download Configuration Guide |
Avaya (Lucent) |
Definity |
DMG3000 (all models) |
BRI-QSIG |
Field Tested |
Avaya (Lucent) |
Definity |
DMG4000 (all models) |
T1-QSIG, E1-QSIG |
Field Tested |
Avaya (Tenovis) |
Integral 3 |
DMG4000 (all models) |
T1-QSIG, E1-QSIG |
Field Tested |
Avaya (Tenovis) |
I55 |
DMG4000 (all models) |
T1-QSIG, E1-QSIG |
Field Tested |
Avaya (Tenovis) |
Integral Enterprise |
DMG4000 (all models) |
T1-QSIG, E1-QSIG |
Field Tested |
Avaya |
S8100 |
DMG1008DNI |
Digital Set Emulation |
Lab Tested |
Avaya |
S8300 |
DMG1008DNI |
Digital Set Emulation |
Lab Tested |
Avaya |
S8500 |
DMG1008DNI |
Digital Set Emulation |
Lab Tested |
Avaya |
S8X00 |
DMG2000 Series (all models) |
E1 QSIG |
Download Configuration Guide |
Avaya |
S8X00 |
DMG2000 Series (all models) |
T1 CAS In Band |
Download Configuration Guide |
Avaya |
S8X00 |
DMG2000 Series (all models) |
T1 QSIG |
Download Configuration Guide |
Avaya |
S8700, S8710 |
DMG1008DNI |
Digital Set Emulation |
Lab Tested |
Avaya |
5ESS |
DMG2000 Series (all models) |
T1-NI2, T1-5ESS |
Lab Tested |
DeTeWe |
OpenCom 1000/1010 |
DMG3000 (all models) |
BRI-QSIG |
Field Tested |
DeTeWe |
OpenCom 1000/1011 |
DMG4000 (all models) |
T1-QSIG, E1-QSIG |
Field Tested |
Ericsson |
MD110 |
DMG1008LS / DMG1004LS |
Serial MD110 |
Download Configuration Guide |
Ericsson |
MD110 |
DMG2000 Series (all models) |
E1 QSIG |
Download Configuration Guide |
Ericsson |
MD110 |
DMG3000 (all models) |
BRI-QSIG |
Field Tested |
Ericsson |
MD110 |
DMG4000 (all models) |
T1-QSIG, E1-QSIG |
Field Tested |
Ericsson |
MD110 Mixed Mode |
DMG3000 (all models) |
BRI-QSIG |
Field Tested |
Ericsson |
MD110 Mixed Mode |
DMG4000 (all models) |
T1-QSIG, E1-QSIG |
Field Tested |
Ericsson |
BP128 |
DMG1008LS / DMG1004LS |
Analog, Serial |
Field Tested |
Ericsson |
BP250 |
DMG2000 Series (all models) |
E1-QSIG |
Field Tested |
Ericsson |
BP250 (Q.SIG Conform) |
DMG3000 (all models) |
BRI-QSIG |
Field Tested |
Ericsson |
BP250 (Q.SIG Conform) |
DMG4000 (all models) |
T1-QSIG, E1-QSIG |
Field Tested |
Ericsson |
BP250 (ETSI Conform) |
DMG3000 (all models) |
BRI-QSIG |
Field Tested |
Ericsson |
BP250 (ETSI Conform) |
DMG4000 (all models) |
T1-QSIG, E1-QSIG |
Field Tested |
Fujitsu |
|
DMG1008LS / DMG1004LS |
Analog In Band DTMF |
Field Tested |
Hitachi |
|
DMG1008LS / DMG1004LS |
Analog In Band DTMF |
Field Tested |
Intecom |
PointSpan M6880 |
DMG1008LS / DMG1004LS |
Analog In Band DTMF |
Lab Tested |
Intecom |
|
DMG2000 Series (all models) |
T1-CAS |
Field Tested |
Matra |
65XX |
DMG3000 (all models) |
BRI-QSIG |
Field Tested |
Matra |
65XX |
DMG4000 (all models) |
T1-QSIG, E1-QSIG |
Field Tested |
Mitel |
3300 |
DMG2000 Series (all models) |
E1 QSIG |
Download Configuration Guide |
Mitel |
3300 |
DMG2000 Series (all models) |
T1 QSIG |
Download Configuration Guide |
Mitel |
3300 |
DMG2000 Series (all models) |
T1-NI2 |
Lab Tested |
Mitel |
SX200 |
DMG1008MTLDNI |
Digital Set Emulation |
Download Configuration Guide |
Mitel |
SX-2000 S, SX-2000 VS |
DMG1008MTLDNI |
Digital Set Emulation |
Lab Tested |
Mitel |
SX-2000 S, SX-2000 VS |
DMG2000 Series (all models) |
T1-QSIG, E1-QSIG, T1-NI2 |
Lab Tested |
NEC |
NEAX2400, NEAX 2400 IPX, NEAX2000IVS2 |
DMG1008DNI |
Digital Set Emulation |
Lab Tested |
NEC |
NEAX 2400 IPX |
DMG2000 Series (all models) |
T1 QSIG |
Download Configuration Guide |
NEC |
NEAX2400IMX |
DMG2000 Series (all models) |
T1 CAS MCI Serial |
Download Configuration Guide |
NEC |
NEAX2400IPX,NEAX2400IMX |
DMG1008DNI |
Digital Set Emulation |
Download Configuration Guide |
|
Nortel |
CS1000 |
DMG2000 Series (all models) |
E1 QSIG |
Download Configuration Guide |
Nortel |
CS1000 |
DMG2000 Series (all models) |
T1-QSIG |
Lab Tested |
Nortel |
CS1000M, S, E |
DMG1008DNI |
Digital Set Emulation |
Lab Tested |
Nortel |
Meridian Option 11 |
DMG2000 Series (all models) |
T1-CAS, T1-QSIG, E1-QSIG, T1-NI2 |
Lab Tested |
Nortel |
Meridian 11C |
DMG1008DNI |
Digital Set Emulation |
Download Configuration Guide |
Nortel |
Meridian 11C |
DMG2000 Series (all models) |
T1 QSIG |
Download Configuration Guide |
Nortel |
Meridian 21 |
DMG1008DNI |
Digital Set Emulation |
Lab Tested |
Nortel |
Meridian 21A |
DMG1008DNI |
Digital Set Emulation |
Lab Tested |
Nortel |
Meridian 51C |
DMG1008DNI |
Digital Set Emulation |
Lab Tested |
Nortel |
Meridian 61C |
DMG1008DNI |
Digital Set Emulation |
Lab Tested |
Nortel |
Meridian 81C |
DMG1008DNI |
Digital Set Emulation |
Lab Tested |
Nortel |
Meridian 11C |
DMG2000 Series (all models) |
E1 QSIG |
Download Configuration Guide |
Nortel |
Meridian |
DMG3000 (all models) |
BRI-QSIG |
Field Tested |
Nortel |
Meridian |
DMG4000 (all models) |
T1-QSIG, E1-QSIG |
Field Tested |
Nortel |
DMS-10, DMS-100 |
DMG1008LS / DMG1004LS |
Analog, Serial |
Field Tested |
Nortel |
DMS-100 |
DMG2000 Series (all models) |
T1-NI2, T1-DMS100 |
Lab Tested |
Nortel |
Option 11C mini |
DMG1008DNI |
Digital Set Emulation |
Lab Tested |
Philips |
Sopho |
DMG2000 Series (all models) |
E1-QSIG |
Lab Tested |
Rolm (Siemens) |
9751 |
DMG1008RLMDNI |
Digital Set Emulation |
Download Configuration Guide |
Rolm (Siemens) |
8000, 9000, 9751 |
DMG1008LS / DMG1004LS |
Analog In Band DTMF |
Lab Tested |
Siemens |
Hicom 150E |
DMG1008LS / DMG1004LS |
Analog In Band DTMF |
Field Tested |
Siemens |
Hicom 150E |
DMG3000 (all models) |
BRI-QSIG |
Field Tested |
Siemens |
Hicom 150E |
DMG4000 (all models) |
T1-QSIG, E1-QSIG |
Field Tested |
Siemens |
Hicom 300 |
DMG1008DNI |
Digital Set Emulation |
Download Configuration Guide |
Siemens |
Hicom 300 |
DMG2000 Series (all models) |
T1 CAS In Band |
Download Configuration Guide |
Siemens |
Hicom 300 |
DMG3000 (all models) |
BRI-QSIG |
Download Configuration Guide |
Siemens |
Hicom 300 |
DMG4000 (all models) |
T1-QSIG, E1-QSIG |
Lab Tested |
Siemens |
Hicom 300ECS |
DMG1008DNI |
Digital Set Emulation |
Lab Tested |
Siemens |
Hicom 300ECS |
DMG2000 Series (all models) |
T1-CAS |
Lab Tested |
Siemens |
Hicom 300E (Euro) |
DMG1008LS / DMG1004LS |
Analog In Band DTMF |
Lab Tested |
Siemens |
Hicom 3000 |
DMG4000 (all models) |
T1-QSIG, E1-QSIG |
Field Tested |
Siemens |
Hicom 3000 |
DMG2000 Series (all models) |
T1-QSIG, E1-QSIG |
Field Tested |
Siemens |
HiPath 4000 |
DMG1008DNI |
Digital Set Emulation |
Lab Tested |
Siemens |
HiPath 4000 |
DMG1008LS / DMG1004LS |
Analog In Band DTMF |
Download Configuration Guide |
Siemens |
HiPath 4000 |
DMG2000 Series (all models) |
T1 QSIG |
Download Configuration Guide |
Siemens |
HiPath 4000 |
DMG2000 Series (all models) |
E1-QSIG, T1-NI2 |
Lab Tested |
Siemens |
HiPath 4000 |
DMG3000 (all models) |
BRI-QSIG |
Download Configuration Guide |
Siemens |
HiPath 4000 |
DMG4000 (all models) |
T1-QSIG, E1-QSIG |
Lab Tested |
Tenovis |
Integral 3 |
DMG2000 Series (all models) |
E1-QSIG |
Lab Tested |
Tenovis |
Integral 3 |
DMG4000 (all models) |
T1-QSIG, E1-QSIG |
Field Tested |
Toshiba |
CTX |
DMG1008LS / DMG1004LS |
Analog Serial |
Download Configuration Guide |
Toshiba |
CTX |
DMG1008LS / DMG1004LS |
Analog In Band DTMF |
Download Configuration Guide |