You are here: CSP Developer’s Guide: Overview > 7 DSP Series 2 Card Product Description > CPA Classes
The parameters associated with a CPA class are defined in CPA Class Parameters and Definitions. To modify a class or to add a new class, use the CPA Class Configure message. The Excel platform supports up to 15 classes. A class can contain up to 15 pattern members, and 30 patterns are allowed for each Excel platform. Class elements are given in CPA Classes.
Class |
Standard N.A. |
Dial Tone |
CPC Det. |
Energy Det. |
---|---|---|---|---|
0x01 |
|
|
Energy Detection |
|
4/250 ms |
|
|
4/500 ms |
|
0x00 |
0x00 |
0x00 |
0x00 |
|
25,000 |
25,000 |
0xFFFF |
25,000 |
|
Confirmation (ms) |
13,000 |
25,000 |
0xFFFF |
13,000 |
22,000 |
15,000 |
0xFFFF |
22,000 |
|
40 |
20 |
20 |
20 |
|
60 |
20 |
20 |
60 |
|
Maximum On Timer (ms) |
2,800 |
25,000 |
0xFFFF |
2,800 |
Maximum Off Timer (ms) |
5,000 |
25,000 |
0xFFFF |
5,000 |
0x0000 |
0x0000 |
0x0000 |
0x0005 |
|
0x0000 |
0x0000 |
0x0000 |
0x0002 |
|
Patterns in Class |
0x01 Ringback |
0x0C PBX Dial Tone 0x0D Standard Dial Tone |
0x0E CPC Detection |
0x01 Ringback 0x02 Double Ringback 0x03 Busy 0x04 Reorder |