You are here: CSP Developer’s Guide: Overview > 8 DSP Series 2 Cards Product Description > CPA Classes
The parameters associated with a CPA class are defined in CPA Pattern Parameter definitions. To modify a class or to add a new class, use the CPA Class Configure message. The CSP supports up to 15 classes. A class can contain up to 15 pattern members, and 30 patterns are allowed for each CSP. Class elements are given in CPA Classes.
Class |
Standard N.A. |
Dial Tone |
CPC Det. |
Energy Det. |
---|---|---|---|---|
Mode |
0x01 |
|
|
Energy Detection |
Tone Burst Answer Threshold |
4/250 ms |
|
|
4/500 ms |
Start Delay |
0x00 |
0x00 |
0x00 |
0x00 |
Continuous Silence Timeout (ms) |
25,000 |
25,000 |
0xFFFF |
25,000 |
Confirmation (ms) |
13,000 |
25,000 |
0xFFFF |
13,000 |
Confirmation/No Report (ms) |
22,000 |
15,000 |
0xFFFF |
22,000 |
Minimum Frequency Glitch Time (ms) |
40 |
20 |
20 |
20 |
Minimum Silence Glitch Time (ms) |
60 |
20 |
20 |
60 |
Maximum On Timer (ms) |
2,800 |
25,000 |
0xFFFF |
2,800 |
Maximum Off Timer (ms) |
5,000 |
25,000 |
0xFFFF |
5,000 |
Mode Specific Value 1 |
0x0000 |
0x0000 |
0x0000 |
0x0005 |
Mode Specific Value 2 |
0x0000 |
0x0000 |
0x0000 |
0x0002 |
Patterns in Class |
0x01 Ringback |
0x0C PBX Dial Tone 0x0D Standard Dial Tone |
0x0E CPC Detection |
0x01 Ringback 0x02 Double Ringback 0x03 Busy 0x04 Reorder |
Table 8-16 2100Hz
2100Hz |
|
---|---|
Pattern ID |
0x14 |
Tone Group ID |
0x00 |
Configuration Bits |
0x00 |
CPA Result on Pattern Loss |
0x14 |
Interval Cycles to Match |
1 |
Interval Cycles to Report |
1 |
Interval Descriptor Count |
1 |
Tone Interval 0: Tone ID |
0x0E |
Reserved |
0x00 |
Minimum Filters (ms) |
640 |
Maximum Filters (ms) |
850 |